August 15, 2017
© Copyright IBM Corporation, 2017 Page 87 of 117
To add a range on the TS7700:
1.
Select
Add
from the Select Action options then press
Go
2.
Enter volsers in the
Start Volser
and End Volser
fields. In this example, a range from B00000 to
B00100 is being defined..
3.
Select a Media Type
compatible with 3592. For this example, the JB media type is being
selected.
4.
Select the
Home Pool
. For this example, pool 9 is being specified and I want the range of volsers
to go to that pool when they are added to the library.
5.
Select the
OK
button.
To expand a range, click on the range presented in the list, select
Modify
from the Select Action
options then press
Go
. Make changes to the Start and/or End Volser fields, select the
OK
button.
To delete a range, click the range presented in the list, select
Delete
from the Select Action options
then press
Go
. On the confirmation screen select
YES
.
If the TS7700 is attached to a 3584 library then set up the Cartridge Assignment Policies per the
instructions in Appendix D for the same ranges