© Copyright IBM Corp. 2004
67
Appendix A. Event messages
The L10 storage switch’s event messages are listed below. For explanations, contact a
customer service representative. The message’s applicable severity level as defined
below are given before each message.
These severity levels can be used to designate which events trigger trap messages.
Using the Command Line Interface (CLI), you can designate the minimum severity level
of events to be logged in the Event Log and at which to illuminate the switch’s Fault LED.
Table 32. Event message severity levels
Severity Level
Severity
Description
1
EMERG
Immediate action required; system failing
2
ALERT
Unrecoverable condition reported; major event in
progress
3
CRIT
Event failed with possible loss of integrity
4
ERR
Condition failed; action required
5
WRN
Failed event occurred; no action required
6
NOTIFY
Configuration error or abnormal event occurred; no
action required
7
INFO
Event occurred; no action required
Table 33. Event messages
Event
Event Message
Severity
1
Message log cleared
INFO
5
Power Supply Failed
ALERT
6
Power Supply Online
NOTIFY
9
Fan has stopped
EMERG
10
Fan has returned
ALERT
19
Temperatures over limit
ALERT
20
Temperature OK
INFO
50
SPF Overvoltage
EMERG
54
SOC has detected a CRC error in the EEPROM
NOTIFY
70
Port # bypassed
NOTIFY
71
Port # inserted
NOTIFY
72
Transceiver detected at Port #
NOTIFY
73
Transceiver removed at Port #
NOTIFY
74
SEOC occurred on Port #
NOTIFY
75
Port # exceeded OS threshold
NOTIFY
76
Port # exceeded CRC threshold
NOTIFY
77
Loop UP on Port #
NOTIFY
78
Loop DOWN on Port #
NOTIFY
79
Port # received a LIP(F8)
WRN
80
Port # CRC Error detected in frame
WRN
81
Port # did not receive LIPF7) within timeout
WRN
Summary of Contents for TotalStorage L10
Page 2: ......
Page 3: ...IBM TotalStorage Storage Switch 2006 Model L10 CLI Reference Guide GC26 7652 00...
Page 8: ...2006 Model L10 Storage Switch vi...
Page 10: ...2006 Model L10 Storage Switch viii...
Page 20: ...2006 Model L10 Storage Switch 8...
Page 66: ...2006 Model L10 Storage Switch 54...
Page 74: ...2006 Model L10 Storage Switch 62...
Page 82: ...2006 Model L10 Storage Switch 70...
Page 84: ...2006 Model L10 Storage Switch 72...
Page 86: ...2006 Model L10 Storage Switch 74...
Page 95: ......
Page 96: ...GC26 7652 00...