Chapter 4. Show menu (root/show)
57
Displaying system information (root/show/sysinfo)
This command displays the current switch information.
To display current switch information:
From the Show menu (root/show), type
sysinfo
and press E
NTER
.
The system information includes the following:
Table 28. System information
Setting
Description
System Name
The name assigned to the switch.
Location
The location assigned to the switch.
MAC ID
A unique device address (MAC address) assigned to each
switch at the factory. Cannot be configured or modified.
Serial Number
A unique identification number assigned to each switch at the
factory. This field can only be configured or modified on Field
Replaceable Units (FRUs).
Switching Mode
When ‘on’, the switch is able to direct data to specific ports
using full bandwidth. When ‘off’, bandwidth is split among the
ports and data is sent around the network as in a shared FC-
AL architecture.
OS Error Threshold
The maximum number of OS errors allowed in a 10-second
interval before a port is bypassed. Setting this value to ‘0’
uses the factory default setting.
CRC Error Threshold
The maximum number of CRC errors allowed in a 10-second
interval before a port is bypassed. Setting this value to ‘0’
uses the factory default setting.
Blocking Arbitration
When two ports start a communication session, the Blocking
ARB is sent to all other ports trying to communicate with
those ports until the connection is terminated. The default
setting is ‘FF’. If other connected devices use the ‘FF’ setting
for another purpose, select another Blocking ARB value (for
example, ‘FB’).
Switch FW Version
The current firmware loaded onto the switch. The current
version can be replaced by an alternate version that you have
previously loaded onto the switch.
SOC Version
The SOC 320 version that is used in the switch. Cannot be
configured or modified.
Switch HW Version
The hardware version of the switch. Cannot be configured or
modified.
MIB Version
The proprietary Management Information Base version that is
supported through SMP. Cannot be configured or modified.
Speed
The current speed per port at which the switch is running. All
ports operate at the same speed. The default switch speed is
set to 2.125 Gb/s.
Summary of Contents for TotalStorage L10
Page 2: ......
Page 3: ...IBM TotalStorage Storage Switch 2006 Model L10 CLI Reference Guide GC26 7652 00...
Page 8: ...2006 Model L10 Storage Switch vi...
Page 10: ...2006 Model L10 Storage Switch viii...
Page 20: ...2006 Model L10 Storage Switch 8...
Page 66: ...2006 Model L10 Storage Switch 54...
Page 74: ...2006 Model L10 Storage Switch 62...
Page 82: ...2006 Model L10 Storage Switch 70...
Page 84: ...2006 Model L10 Storage Switch 72...
Page 86: ...2006 Model L10 Storage Switch 74...
Page 95: ......
Page 96: ...GC26 7652 00...