Table 11. RAID controller LEDs (continued)
Icon
LED
Color
Operating states
1
Expansion
port bypass
Amber
v
Off
- Normal operation.
v
On
- One of the following situations has
occurred:
– An SFP module is inserted in the drive
loop port and the fibre-channel cable is
not attached to it.
– The fibre-channel cable is not attached
to an expansion unit.
– The attached expansion unit is not
turned on.
– An SFP has failed, a fibre-channel
cable has failed, or an SFP has failed
on the attached expansion unit.
Expansion
loop
Green
v
On
- Normal operation.
v
Off
- The RAID controller circuitry has
failed, or the RAID controller has no
power.
2Gbps
2Gbps
Green
v
On
- Normal operation (host connection is
at 2Gbps).
v
Off
- Host connection is at 1Gbps (which
is not supported for controller firmware
05.33.xx.xx.
10BT
10BT
Green
v
If the Ethernet connection is 10BASE-T:
The 10BT LED is on, 100BT LED flashes
faintly.
v
If the Ethernet connection is
100BASE-T:
10BT LED is off, 100BT LED
is on.
v
If there is no Ethernet connection
- Both
LEDs are off.
100BT
100BT
1
Always use the storage-management software to identify the failure.
Power supply
fault LEDs
Power LED
Fan fault LED
Fan fault LED
Power LED
Figure 37. Fan and power supply LEDs
Chapter 4. Operating the storage server
45
Summary of Contents for TotalStorage FAStT600
Page 2: ......
Page 8: ...vi IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Page 12: ...x IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Page 16: ...xiv IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Page 30: ...xxviii IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Page 40: ...10 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Page 78: ...48 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Page 102: ...72 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Page 108: ...78 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Page 114: ...84 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Page 122: ...92 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Page 128: ...98 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Page 133: ......
Page 134: ...Part Number 24P8202 Printed in U S A GC26 7531 01 1P P N 24P8202...