Operator Panel Display Numbers
E-3
Power-On Self-Test (POST) Indicators
20c
L2 cache POST error. (The display shows a solid 20c for 5 seconds.)
21c
L2 cache is not detected. (The display shows a solid 21c for 2 seconds.)
22c
Attempting a normal mode IPL from FDDI specified in NVRAM IPL device
list.
23c
Attempting a normal mode IPL from FDDI specified in IPL ROM device list.
24c
Attempting a service mode IPL from FDDI specified in NVRAM IPL device
list.
25c
Attempting a service mode IPL from FDDI specified in IPL ROM device list.
200
IPL attempted with keylock in the Secure position.
201
IPL ROM test failed or checkstop occurred (irrecoverable).
202
Unexpected machine check interrupt.
203
Unexpected data storage interrupt.
204
Unexpected instruction storage interrupt.
205
Unexpected external interrupt.
206
Unexpected alignment interrupt.
207
Unexpected program interrupt.
208
Unexpected floating point unavailable interrupt.
209
Unexpected SVC interrupt.
210
Unexpected SVC interrupt.
211
IPL ROM CRC comparison error (irrecoverable).
212
RAM POST memory configuration error or no memory found
(irrecoverable).
213
RAM POST failure (irrecoverable).
214
Power status register failed (irrecoverable).
215
A low voltage condition is present (irrecoverable).
216
IPL ROM code being uncompressed into memory.
217
End of boot list encountered.
218
RAM POST is looking for good memory.
219
RAM POST bit map is being generated.
220
IPL control block is being initialized.
221
NVRAM CRC comparison error during AIX IPL(key mode switch in Normal
mode). Reset NVRAM by reaccomplishing IPL in Service mode. For
systems with an internal, direct-bus-attached (DBA) disk, IPL ROM
attempted to perform an IPL from that disk before halting with this operator
panel display value.
222
Attempting a Normal mode IPL from Standard I/O planar-attached devices
specified in NVRAM IPL Devices List.
223
Attempting a Normal mode IPL from SCSI-attached devices specified in
NVRAM IPL Devices List.
224
Attempting a Normal mode IPL from 9333 subsystem device specified in
NVRAM IPL Devices List.
225
Attempting a Normal mode IPL from 7012 DBA disk-attached devices
specified in NVRAM IPL Devices List.
226
Attempting a Normal mode IPL from Ethernet specified in NVRAM IPL
Devices List.
227
Attempting a Normal mode IPL from Token-Ring specified in NVRAM IPL
Devices List.
228
Attempting a Normal mode IPL from NVRAM expansion code.
229
Attempting a Normal mode IPL from NVRAM IPL Devices List; cannot IPL
from any of the listed devices, or there are no valid entries in the Devices
List.
Summary of Contents for ThinkPad R30
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Operator Guide...
Page 12: ...xii Operator Guide...
Page 16: ...xvi Operator Guide...
Page 20: ...1 4 Operator Guide...
Page 132: ...4 10 Operator Guide AC Rack Cables and the CPU Enclosure Connectors CPU Enclosure...
Page 156: ...6 4...
Page 194: ...10 4 Operator Guide...
Page 238: ...B 8 Operator Guide...
Page 248: ...D 4 Operator Guide...