SystemGuard Remote Operation Configuration
C-1
Appendix C. SystemGuard Remote Operation
Configuration
To use the remote operation capabilities of SystemGuard and also allow console mirroring,
you must have flags, parameters and tty configurations properly enabled. Below, are tty0
and tty1 settings, sample modem files and all the parameters that are necessary to allow
remote operations.
Terminal Configuration
The configuration of the tty0 for the S1 port looks similar to the following:
[TOP] [Entry Fields]
TTY tty0
TTY type tty
TTY interface rs232
Description Asynchronous
Terminal
Status Available
Location 00–00–S1–00
Parent adapter sa0
PORT number [s1]
Enable LOGIN disable
BAUD rate [9600]
PARITY [none]
BITS per character [8]
Number of STOP BITS [1]
TIME before advancing to next port setting [0]
TERMINAL type [dumb]
FLOW CONTROL to be used [xon]
OPEN DISCIPLINE to be used [dtropen]
STTY attributes for RUN time [hupcl,cread,brkint,
icrnl,opost,tab3,
onlcr,isig,icanon,
echo,echoe,echok,
echoctl,echoke,
imaxbel,iexten]
STTY attributes for LOGIN [hupcl,cread,echoe,
cs8,ixon,ixoff]
LOGGER name []
STATUS of device at BOOT time [available]
TRANSMIT buffer count [16]
RECEIVE trigger level [3]
STREAMS modules to be pushed at OPEN time [ldterm,tioc]
INPUT map file [none]
OUTPUT map file [none]
CODESET map file [sbcs]
Summary of Contents for ThinkPad R30
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Operator Guide...
Page 12: ...xii Operator Guide...
Page 16: ...xvi Operator Guide...
Page 20: ...1 4 Operator Guide...
Page 132: ...4 10 Operator Guide AC Rack Cables and the CPU Enclosure Connectors CPU Enclosure...
Page 156: ...6 4...
Page 194: ...10 4 Operator Guide...
Page 238: ...B 8 Operator Guide...
Page 248: ...D 4 Operator Guide...