Three-Digit Display Numbers
B-7
597
OCS software being configured.
598
OCS hosts being configured during system reboot.
599
Configuring FDDI data link control.
5c0
Streams-based hardware drive being configured.
5c1
Streams-based X.25 protocol being configured.
5c2
Streams-based X.25 COMIO emulator driver being configured.
5c3
Streams-based X.25 TCP/IP interface driver being configured.
5c4
FCS adapter device driver being configured.
5c5
SCB network device driver for FCS is being configured.
5c6
AIX SNA channel being configured.
600
Starting network boot portion of /sbin/rc.boot
602
Configuring network parent devices.
603
/usr/lib/methods/defsys, /usr/lib/methods/cfgsys, or
/usr/lib/methods/cfgbus failed.
604
Configuring physical network boot device.
605
Configuration of physical network boot device failed.
606
Running /usr/sbin/ifconfig on logical network boot device.
607
/usr/sbin/ifconfig failed.
608
Attempting to retrieve the client.info file with tftp. Note that a flashing 608
indicates multiple attempt(s) to retrieve the client_info file are occurring.
609
The client.info file does not exist or it is zero length.
610
Attempting remote mount of NFS file system.
611
Remote mount of the NFS file system failed.
612
Accessing remote files; unconfiguring network boot device.
614
Configuring local paging devices.
615
Configuration of a local paging device failed.
616
Converting from diskless to dataless configuration.
617
Diskless to dataless configuration failed.
618
Configuring remote (NFS) paging devices.
619
Configuration of a remote (NFS) paging device failed.
620
Updating special device files and ODM in permanent filesystem with data
from boot RAM filesystem.
622
Boot process configuring for operating system installation.
650
IBM SCSD disk drive being configured.
680
POWER GXT800M Graphics Adapter
689
4.5GB Ultra SCSI Single Ended Disk Drive being configured.
690
9.1GB Ultra SCSI Single Ended Disk Drive being configured.
694
Eicon ISDN DIVA MCA Adapter for PowerPC Systems.
700
Progress indicator. A 1.1 GB 8-bit SCSI disk drive being identified or
configured.
701
Progress indicator. A 1.1 GB 16-bit SCSI disk drive is being identified or
configured.
702
Progress indicator. A 1.1 GB 16-bit differential SCSI disk drive is being
identified or configured.
703
Progress indicator. A 2.2 GB 8-bit SCSI disk drive is being identified or
configured.
704
Progress indicator. A 2.2 GB 16-bit SCSI disk drive is being identified or
configured.
705
The configuration method for the 2.2 GB 16-bit differential SCSI disk drive is
being run. If an irrecoverable error occurs, the system halts.
706
Progress indicator. A 4.5 GB 16-bit SCSI disk drive is being identified or
configured.
707
Progress indicator. A 4.5 GB 16-bit differential SCSI disk drive is being
identified or configured.