If no serial ports are configured, none are listed. If you want to configure serial ports that are not
listed, continue with the remaining steps.
3. Identify the serial port(s) with the modem(s).
4. Type
smit tty
5. Select
add tty
6. Select
RS232
7. Select
Baud rate 9600
or higher.
8. Select
login enable
and set the flow control to RTS.
9. Commit the selections and set up any other needed serial ports.
10. Exit SMIT.
Appendix D. Service Processor Setup and Test
151