3.5.8.1 URC 9tpx
t=1, 3, or 6
p=1 through 8
x=0, 1, 2, 3, or F
A second disk drive failure has occurred on a 3514: The failure reported
by this URC must be corrected before any other service is performed on
this 3514. The first failing disk drive will be exchanged later.
To correct this error, perform the following:
1. To prevent data loss, the disk drive in the slot indicated by the
third rightmost position of the URC must be returned to the 3514
configuration.
2. Using the control panel, enter the following sequence of commands:
3. Set the 3514 offline:
9 1 7 0 PICTURE 116
A display of 90FF indicates that the 3514 is offline.
4. This error may have been caused by electrical noise or an unseated
cable. Attempt to reset this disk drive by performing the procedure
"Reset Disk Drive" in topic 4.5.7. Then, continue with the next step.
5. Did the procedure "Reset Disk Drive" complete without an error?
No Yes
Go to step 26.
6. Use the URC error log to find the URC that occurred during the
exchange command in step 5. The URC is the 4 leftmost characters in
the error log entry. (See "Using the 3514 Unit Reference Code (URC)
Error Log" in topic 2.6.)
7. Is the rightmost character of the URC (the fourth character in the
error log entry) a 0 or 3?
No Yes
Go to step 11.
8. Exchange the controller card using the exchange procedure "Controller
Card" in topic 4.5.8. Then return to step 9 in this procedure.
CAUTION:
The controller card contains a lithium battery. To avoid possible
explosion, do not burn, exchange, or charge the battery. Discard the
controller card as instructed by local regulations for lithium
batteries. (RSFTC228)
+--------------------------------------------------------------------+
¦ Location ¦ Description ¦
+----------------------+---------------------------------------------¦
¦ D ¦ Controller card (see Caution notice) ¦
+--------------------------------------------------------------------¦
¦ Note: See the "Failing Item Table" in topic 3.3 for the correct ¦
¦ part number for a specific FRU part. ¦
+--------------------------------------------------------------------+
9. Set the Power switch to the On position.
After 3 minutes, is 3514CE27 or the same URC that initiated this
repair action (35149tpx) displayed on the 3514 control panel?
Yes No
Go to step 26.
10. Set the 3514 offline:
3514 Service Information
URC 9tpx
¦ Copyright IBM Corp. 1992, 1993
3.5.8.1 - 1