¦ 86n9 ¦ A disk drive was improperly ¦ ¦ ¦ ¦
¦ ¦ substituted in the disk array ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦ ¦
¦ ¦ Perform "Problem Recovery ¦ ¦ ¦ ¦
¦ ¦ Procedure 4d" in ¦ ¦ ¦ ¦
¦ ¦ topic 3.5.11. ¦ ¦ ¦ ¦
+------+-------------------------------+----------+-----------+----------¦
¦ 86nA ¦ Predictive Failure Analysis ¦ 86F0110 ¦ 100 ¦ Slot 1-8 ¦
¦ ¦ threshold reached ¦ ¦ ¦ ¦
+------+-------------------------------+----------+-----------+----------¦
¦ 86nB ¦ Predictive Failure Analysis ¦ 86F0110 ¦ 100 ¦ Slot 1-8 ¦
¦ ¦ threshold reached ¦ ¦ ¦ ¦
+------+-------------------------------+----------+-----------+----------¦
¦ 86nC ¦ Command issued to disk drive ¦ 86F0110 ¦ 100 ¦ Slot 1-8 ¦
¦ ¦ not supported ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦ ¦
¦ ¦ The system has issued an ¦ ¦ ¦ ¦
¦ ¦ invalid command to the 9337 ¦ ¦ ¦ ¦
¦ ¦ disk unit. ¦ ¦ ¦ ¦
+------+-------------------------------+----------+-----------+----------¦
¦ 86nF ¦ LRC error ¦ 86F0110 ¦ 100 ¦ Slot 1-8 ¦
¦ ¦ ¦ ¦ ¦ ¦
¦ ¦ Perform "Problem Recovery ¦ ¦ ¦ ¦
¦ ¦ Procedure 6a" in ¦ ¦ ¦ ¦
¦ ¦ topic 3.5.12. ¦ ¦ ¦ ¦
+------+-------------------------------+----------+-----------+----------¦
¦ 8Fn0 ¦ Device error, position n ¦ 16G7002 ¦ 100 ¦ Slot 1-8 ¦
¦ ¦ ¦ 16G7003 ¦ ¦ ¦
¦ ¦ ¦ 86F0110 ¦ ¦ ¦
+------+-------------------------------+----------+-----------+----------¦
¦ 8Fn1 ¦ Bus parity error, device n ¦ 16G7002 ¦ 49 ¦ Slot 1-8 ¦
¦ ¦ ¦ 16G7003 ¦ ¦ ¦
¦ ¦ ¦ 86F0110 ¦ ¦ ¦
¦ ¦ ¦ 16G6990 ¦ 49 ¦ D ¦
¦ ¦ ¦ 86F0843 ¦ 02 ¦ Slot 1-8 ¦
+------+-------------------------------+----------+-----------+----------¦
¦ 8Fn2 ¦ Communications failure, ¦ 16G7002 ¦ 48 ¦ Slot 1-8 ¦
¦ ¦ device n ¦ 16G7003 ¦ ¦ ¦
¦ ¦ ¦ 86F0110 ¦ ¦ ¦
¦ ¦ ¦ 16G6990 ¦ 48 ¦ D ¦
¦ ¦ ¦ 86F0843 ¦ 02 ¦ Slot 1-8 ¦
¦ ¦ ¦ 85F7839 ¦ 02 ¦ Slot 1-8 ¦
+------+-------------------------------+----------+-----------+----------¦
¦ 8Fn3 ¦ Device error, position n ¦ 16G7002 ¦ 100 ¦ Slot 1-8 ¦
¦ ¦ ¦ 16G7003 ¦ ¦ ¦
¦ ¦ ¦ 86F0110 ¦ ¦ ¦
+------+-------------------------------+----------+-----------+----------¦
¦ 8Fn9 ¦ A disk drive was improperly ¦ ¦ ¦ ¦
¦ ¦ substituted in the disk array ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦ ¦
¦ ¦ Perform "Problem Recovery ¦ ¦ ¦ ¦
¦ ¦ Procedure 4d" in ¦ ¦ ¦ ¦
¦ ¦ topic 3.5.11. ¦ ¦ ¦ ¦
+------+-------------------------------+----------+-----------+----------¦
¦ 8FnA ¦ Predictive Failure Analysis ¦ 16G7002 ¦ 100 ¦ Slot 1-8 ¦
¦ ¦ threshold reached ¦ 16G7003 ¦ ¦ ¦
¦ ¦ ¦ 86F0110 ¦ ¦ ¦
+------+-------------------------------+----------+-----------+----------¦
¦ 8FnB ¦ Predictive Failure Analysis ¦ 16G7002 ¦ 100 ¦ Slot 1-8 ¦
¦ ¦ threshold reached ¦ 16G7003 ¦ ¦ ¦
¦ ¦ ¦ 86F0110 ¦ ¦ ¦
+------+-------------------------------+----------+-----------+----------¦
¦ 8FnC ¦ Command issued to disk drive ¦ 16G7002 ¦ 100 ¦ Slot 1-8 ¦
¦ ¦ not supported ¦ 16G7003 ¦ ¦ ¦
¦ ¦ ¦ 86F0110 ¦ ¦ ¦
¦ ¦ The system has issued an ¦ ¦ ¦ ¦
¦ ¦ invalid command to the 9337 ¦ ¦ ¦ ¦
¦ ¦ disk unit. ¦ ¦ ¦ ¦
+------+-------------------------------+----------+-----------+----------¦
¦ 8FnF ¦ LRC error ¦ 16G7002 ¦ 100 ¦ Slot 1-8 ¦
¦ ¦ ¦ 16G7003 ¦ ¦ ¦
¦ ¦ Perform "Problem Recovery ¦ 86F0110 ¦ ¦ ¦
¦ ¦ Procedure 6a" in ¦ ¦ ¦ ¦
¦ ¦ topic 3.5.12. ¦ ¦ ¦ ¦
+------+-------------------------------+----------+-----------+----------¦
¦ 90FF ¦ Disk unit offline ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦ ¦
¦ ¦ To isolate the problem, see ¦ ¦ ¦ ¦
¦ ¦ "Analyzing No-Response ¦ ¦ ¦ ¦
¦ ¦ Problems" in topic 1.4. ¦ ¦ ¦ ¦
+------+-------------------------------+----------+-----------+----------¦
¦ 91n0 ¦ Device error, position n ¦ 73F8994 ¦ 100 ¦ Slot 1-8 ¦
¦ ¦ ¦ 16G7002 ¦ ¦ ¦