2.4 How to Switch-On Power to the 3514
1. The Power switch is located on the front of the 3514 in the upper
right corner.
Set the Power switch to the On position.
PICTURE 39
2. Observe the condition of the Unit Ready light, the Unit Attention
light, and the characters that are displayed on the Data display.
Note: The 3514 is ready approximately 3 minutes after the Power
switch is set to the On position. During this time, a series of
4-character codes that start with BB followed by two numbers (BBnn)
are displayed.
The 3514 power is on and the 3514 is ready when either *000, B000, or
BBA0 is continuously displayed, the Unit Ready light is on, and the
Unit Attention light is off continuously.
Note: When B000 or BBA0 is displayed, the 3514 is ready, but has not
communicated with the host system.
PICTURE 40
Any display other than *000 that appears on the Data display after
approximately 3 minutes indicates that service is needed.
Is *000 on the Data display?
Yes No
Go to "Starting Problem Analysis" in topic 1.2.
3. The 3514 power is now switched on and is communicating with the host
system.
3514 Service Information
How to Switch-On Power to the 3514
¦ Copyright IBM Corp. 1992, 1993
2.4 - 1