Table 10. Sensor information, event description, and service action for the 5104-22C, 9006-12P,
9006-22C, or 9006-22P (continued)
Sensor name (Sensor ID)
Event description
Service action
• P1-DIMMA1 Func (0x10)
• P1-DIMMA2 Func (0x11)
• P1-DIMMB1 Func (0x12)
• P1-DIMMB2 Func (0x13)
• P1-DIMMC1 Func (0x14)
• P1-DIMMC2 Func (0x15)
• P1-DIMMD1 Func (0x16)
• P1-DIMMD2 Func (0x17)
• P2-DIMMA1 Func (0x18)
• P2-DIMMA2 Func (0x19)
• P2-DIMMB1 Func (0x1A)
• P2-DIMMB2 Func (0x1B)
• P2-DIMMC1 Func (0x1C)
• P2-DIMMC2 Func (0x1D)
• P2-DIMMD1 Func (0x1E)
• P2-DIMMD2 Func (0x1F)
Configuration Error
Complete the following steps:
a. If the sensor name is P1-
DIMMA1 Func, ensure that
P1-DIMMA1 is seated
properly. If the sensor name
is P1-DIMMA2 Func, ensure
that P1-DIMMA2 is seated
properly. And so on.
b. If you recently installed or
replaced memory DIMMs,
ensure that the DIMMs are
plugged in the correct
memory slots.
c. If the sensor name is P1-
DIMMA1 Func, replace P1-
DIMMA1. If the sensor name
is P1-DIMMA2 Func, replace
P1-DIMMA2. And so on. Go to
on page 91 to identify the
physical location and removal
and replacement procedure.
Beginning troubleshooting and problem analysis 31