Did all the enclosures power on?
Yes:
Go to step 3.
↓
Go to step 3.
No:
Continue with the next step.
2.
Choose from the following options:
v
If the original problem was that an enclosure would not power on and you have another FRU to replace, locate
and replace the next field-replaceable unit (FRU).
v
If the next FRU in the FRU list is an isolation procedure, perform the isolation procedure.
v
If the original problem was that an enclosure would not power on and you have an isolation procedure to
complete, perform the isolation procedure.
v
If the original problem was that an enclosure would not power on and there are no more FRUs or isolation
procedures in the FRU list, contact your next level of support.
v
If you have a new problem, perform problem analysis and repair the new problem.
3.
Load the operating system.
Did the operating system load successfully?
Yes:
Go to step 5.
No:
Continue with the next step.
4.
Choose from the following options:
v
If the original problem was a failing disk drive that contained the operating system software, go to step 5.
v
If the original problem was that the operating system would not load and you have another FRU to replace, go to
your FRU locations section to locate the next FRU.
v
If the next FRU in the FRU list is an isolation procedure, perform the isolation procedure.
v
If the original problem was that the operating system would not load and you have an isolation procedure to
complete, perform the isolation procedure.
v
If the original problem was that the operating system would not load and there are no more FRUs or isolation
procedures in the FRU list, contact your next level of support.
v
If you have a new problem, perform problem analysis and repair the new problem.
5.
Choose from the following options:
v
v
“Verifying the repair in Linux” on page 152
v
“Verifying a repair by using an IBM i system or logical partition” on page 151
Verifying the repair in AIX
You can use this procedure to verify that a repair is complete using the AIX operating system.
Use this maintenance analysis procedure (MAP) to check out the server after a repair is completed.
1.
Did you replace a disk drive in the root volume group?
No
Go to step 3 on page 148.
Yes
Continue with the next step.
2.
Run stand-alone diagnostics either from a CD or from a Network Installation Management (NIM)
server.
Common service procedures
147
Summary of Contents for Power System POWER7 Series
Page 1: ...Power Systems Common service procedures...
Page 2: ......
Page 3: ...Power Systems Common service procedures...
Page 8: ...vi...
Page 125: ...Figure 48 Lift up on the EMC shield Common service procedures 111...
Page 139: ...Figure 60 Lift up on the EMC shield Common service procedures 125...
Page 186: ...172...
Page 196: ...182...
Page 197: ......
Page 198: ...Printed in USA...