Removing the disk drive
1.
From the IBM Power RAID Configuration Utility display, select
Work with disk unit recovery
. Press
Enter.
2.
From the Work with Disk Unit Recovery display, select
Concurrent remove device
. Press Enter. A
Concurrent Device Remove display is shown, similar to the following display.
3.
Type option
1
(Select) next to the location for the disk drive you want to replace. Press Enter.
4.
The Verify Device Concurrent Remove display is shown. The concurrent maintenance light turns on
for that disk drive slot.
5.
On the Verify Device Concurrent Remove display, verify that the selected disk drive is the disk drive
you want to replace, then press Enter. The identify light turns on for the disk drive.
Note:
Ensure that the disk drive is not in use to prevent loss of data.
6.
The Complete Device Concurrent Remove display is shown.
Attention:
v
Attach a wrist strap to an unpainted metal surface of your hardware to prevent electrostatic
discharge (ESD) from damaging your hardware.
v
When using a wrist strap, follow all electrical safety procedures. A wrist strap is for static control.
It does not increase or decrease your risk of receiving electric shock when using or working on
electrical equipment.
v
If you do not have a wrist strap, just prior to removing the product from ESD packaging and
installing or replacing hardware, touch an unpainted metal surface of the system for a minimum
of 5 seconds.
7.
Squeeze and pull the handle of the disk drive out toward you before you remove the disk drive as
shown in Figure 29 on page 93 or Figure 30 on page 93. If the handle is not all the way out, the disk
Concurrent Device Remove
Choose a single location for remove operations
1=Select
OPT Name
PCI/SCSI Location
Description
Status
--- ------ -------------------------- ------------------------- -----------------
sdc
0000:41:01.0.1/0:8:0
Physical Disk
Active
0000:41:01.0.1/0:5:
Empty
sdb
0000:41:01.0.1/0:4:0
Physical Disk
Active
sda
0000:41:01.0.1/0:3:0
Physical Disk
Active
0000:41:01.0.1/1:8:
Empty
sdf
0000:41:01.0.1/1:5:0
Physical Disk
Active
sde
0000:41:01.0.1/1:4:0
Physical Disk
Active
sdd
0000:41:01.0.1/1:3:0
Physical Disk
Active
0001:61:01.0.2/0:8:
Empty
sdh
0001:61:01.0.2/0:9:0
Physical Disk
Active
sdg
0001:61:01.0.2/0:3:0
Physical Disk
Active
Figure 28. Example Concurrent Device Remove display
92
Summary of Contents for Power System POWER7 Series
Page 1: ...Power Systems Common service procedures...
Page 2: ......
Page 3: ...Power Systems Common service procedures...
Page 8: ...vi...
Page 125: ...Figure 48 Lift up on the EMC shield Common service procedures 111...
Page 139: ...Figure 60 Lift up on the EMC shield Common service procedures 125...
Page 186: ...172...
Page 196: ...182...
Page 197: ......
Page 198: ...Printed in USA...