Verifying a repair by using an IBM i system or logical partition
Use this procedure to verify a repair by using the IBM i operating system.
1.
Was the system powered off during the repair?
Yes:
Continue with the next step.
No:
Continue with step 3.
2.
Perform the following tasks:
a.
Verify that the power cable is plugged into the power outlet.
b.
Verify that power is available at the customer's power outlet.
3.
Was the partition powered off during the repair?
Yes:
Continue with the next step.
No:
Continue with step 6.
4.
Select the IPL type and mode for the system or logical partition that the customer uses (see IPL type
mode and speed options in the Service functions).
5.
Start an IPL by powering on the system or partition (see Powering on and powering off). Did the
system complete the IPL?
Yes:
Continue with the next step.
No:
This might be a new problem. Go to the Starting a repair action.
This ends the procedure.
6.
Did the system or partition remain running throughout the repair, and was the I/O processor, I/O
adapter, or storage device replaced?
Yes:
Continue with step 10.
No:
Continue with the next step.
7.
Use the service action log or serviceable event view (if the system is managed by an HMC) to look
for any reference codes that are related to this IPL (see Searching the service action log). Are there
any reference codes that are related to this IPL?
Yes:
Continue with the next step.
No:
If the problem was related to removable media or communications, perform the verification
procedures in the Service functions to verify that the problem is corrected. Then return the
system to the customer and have the customer verify the system date and time.
This ends the
procedure.
8.
Is the new reference code the same as the original reference code?
Yes:
Continue with the next step.
No:
A new symptom might have occurred. Go to the Start of call procedure.
This ends the
procedure.
9.
Are there any other failing items that remain to be replaced?
Yes:
Replace the next failing item listed for this reference code.
This ends the procedure.
No:
Contact your next level of support for assistance.
This ends the procedure.
10.
Was concurrent maintenance performed on an optical storage unit?
Yes:
The product activity log and service action log, in most cases, contain a reference code for
the optical storage unit when concurrent maintenance is performed. You can ignore this reference
code. Perform the following:
- Perform the verification procedures in the Service functions topic to verify that the problem is
corrected.
- Return the system to the customer and have the customer verify the system date and time.
This
ends the procedure.
No:
Continue with the next step.
11.
Use the service action log to look for any new reference codes (see Using the Service Action Log).
Are there any new reference codes?
Common service procedures
151
Summary of Contents for Power System POWER7 Series
Page 1: ...Power Systems Common service procedures...
Page 2: ......
Page 3: ...Power Systems Common service procedures...
Page 8: ...vi...
Page 125: ...Figure 48 Lift up on the EMC shield Common service procedures 111...
Page 139: ...Figure 60 Lift up on the EMC shield Common service procedures 125...
Page 186: ...172...
Page 196: ...182...
Page 197: ......
Page 198: ...Printed in USA...