21.
Reconnect the front SAS cables to the disk drive backplane. Push the connectors in until the latch
clicks.
Notes:
v
The short SAS cable connects the upper disk drive backplane connector (J2) to the P2 connector on
the adapter in slot P1-C14. The long SAS cable connects the lower disk drive backplane connector
(J1) to the P1 connector on the adapter in slot P1-C15. See Figure 8.
v
For information about SAS cable part numbers, see 5148-21L, 5148-22L, 8247-21L, 8247-22L,
8284-21A, or 8284-22A system parts (http://www.ibm.com/support/knowledgecenter/POWER8/
p8ecs/p8ecs_83x_8rx_parts.htm).
22.
Replace the fan cage with the fans installed. For instructions, see Replacing a fan cage
(http://www.ibm.com/support/knowledgecenter/POWER8/p8haq/
p8haq_83x_8rx_fancagereplace.htm).
P8EG5506-0
Figure 7. Reconnecting the front SAS cables in the disk drive backplane
J2
J1
Storage Controller
(CCIN 57D7)
Slot C14
P2
P1
Storage Controller
(CCIN 57D7)
Slot C15
P2
P1
Long
Cable
Short
Cable
P8EG750
1-0
Base DASD Backplane
(CCIN 2B09)
Figure 8. Reconnecting the SAS cable in a split-disk configuration
PCIe3 x8 SAS RAID internal adapter 6 Gb
7
Summary of Contents for PCIe3 x8 SAS RAID internal adapter 6 Gb
Page 2: ......
Page 8: ...vi PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 18: ...xvi PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 36: ...18 PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 118: ...100 PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 129: ...Notices 111 ...
Page 130: ...IBM Printed in USA ...