![IBM PCIe3 x8 SAS RAID internal adapter 6 Gb Manual Download Page 109](http://html.mh-extra.com/html/ibm/pcie3-x8-sas-raid-internal-adapter-6-gb/pcie3-x8-sas-raid-internal-adapter-6-gb_manual_606017109.webp)
e.
Click Commit after you make your selection.
Note:
If the terminal type is not defined, you are prompted to define it before you can proceed.
28.
Exit from diagnostics in this partition and return to the AIX command prompt.
29.
Have all the partitions in the list of all partitions you recorded in step 11 on page 90 been processed?
v
Yes:
Continue with the next step.
v
No:
Go to step 25 on page 90 to process the next partition in the list you recorded in step 11 on
30.
Have all the serviceable events recorded in step 4 on page 89 been processed?
v
Yes:
Continue with the next step.
v
No:
Go to step 5 on page 89 and process the next service action event in the list of serviceable
events recorded in step 4 on page 89.
31.
While processing all service action events, were you directed to step 14 on page 90?
v
Yes:
Continue with the next step.
v
No:
If the system attention LED is still on, turn off the LED as described in “Activating and
deactivating LEDs.” Return the system to the customer. This completes the repair.
Note:
If during the processing of the list of open service action events, some service action events
remained open, further service actions might be required to complete the repair.
32.
Complete all the following steps for each entry in the list of Axx partitions you began recording in
step 14 on page 90, except for the partition you were using to debug the original problem.
33.
From the list of Axx partitions, open the management console virtual terminal window of a partition
, and then type
diag
at the AIX command prompt.
34.
When the diagnostic operating instructions are displayed, complete the following steps:
a.
Press Enter.
b.
Select the Task Selection option.
Note:
If the terminal type is not defined, you are prompted to define it before you can proceed.
c.
Select the Log Repair option.
d.
Select the resource associated with the repair action:
v
If the repair action was reseating a cable or adapter, select the resource associated with that
repair action.
v
If the resource associated with your repair action is not displayed on the Resource List, select
sysplanar0
.
e.
Click Commit after you make your selection.
35.
Exit from diagnostics in this partition and return to the AIX command prompt.
36.
Have all the partitions in the list of Axx partitions you began recording in step 14 on page 90 been
processed?
v
Yes:
Continue with the next step.
v
No:
Go to step 32 to process the next partition in the list you recorded in step 14 on page 90.
37.
If the system attention LED is still on, turn off the LED as described in “Activating and deactivating
LEDs.” This completes the repair. Return the system to the customer.
Note:
If, during the processing of the list of open service action events, some service action events
remained open, further service actions might be required to complete the repair.
Activating and deactivating LEDs
You can use these procedures to activate or deactivate light-emitting diodes (LEDs) by using the
management console or the Advanced System Management Interface (ASMI).
Common procedures for removing or replacing the PCIe3 x8 SAS RAID internal adapter 6 Gb
91
Summary of Contents for PCIe3 x8 SAS RAID internal adapter 6 Gb
Page 2: ......
Page 8: ...vi PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 18: ...xvi PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 36: ...18 PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 118: ...100 PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 129: ...Notices 111 ...
Page 130: ...IBM Printed in USA ...