Chapter 7. Solving problems
127
35
ServeRAID
Aborted
Test setup error: No ServeRAID adapter found
on system board or PCI bus
Make sure the
ServeRAID adapter is
properly installed.
If the problem
remains, replace the
ServeRAID adapter.
If the problem persists,
call for service.
Failed
Adapter in slot n; adapter/drive configuration
error
(where n is the slot number of the failing
adapter)
Run the ServeRAID
Configuration Utility.
If the problem
remains, replace the
ServeRAID adapter in
slot n.
If the problem persists,
call for service.
Adapter in slot n; internal error
(where n is the slot number of the failing
adapter)
Logical drive m on adapter in slot n
(where m is the number of the failing logical
drive and n is the slot number of the adapter)
On system board; internal error
Run the ServeRAID
Configuration Utility.
If the problem persists,
call for service.
On system board; adapter/drive configuration
error
Logical drive on system board adapter
Adapter in slot n; memory allocation error
(where n is the slot number of the failing
adapter)
Call for service.
On system board; memory allocation error
On system board; PCI configuration error
On system board; POST error
Adapter in slot n; POST error
(where n is the slot number of the failing
adapter)
Replace the
ServeRAID adapter in
slot n. If the problem
persists, call for
service.
Adapter in slot n; PCI configuration error
(where n is the slot number of the failing
adapter)
SCSI drive on adapter in slot n, SCSI ID m
(where n is the slot number of the adapter and m
is the SCSI ID of the drive)
Check the cable and
power connections on
the drive. If the
problem persists, call
for service.
075
Power supply
Failed
Voltage sensed by the system is out of range
Call for service.
Code
Function
Result
Text message
Action
Table 17. Diagnostic error messages
Summary of Contents for Netfinity 4500R
Page 1: ...IBM IBM Netfinity 4500R User s Reference SC19 K080 60...
Page 2: ......
Page 3: ...IBM IBM Netfinity 4500R User s Reference SC19 K080 60...
Page 10: ...viii IBM Netfinity 4500R User s Reference Safety...
Page 32: ...20 IBM Netfinity 4500R User s Reference Using the SCSISelect utility program...
Page 70: ...58 IBM Netfinity 4500R User s Reference Netfinity Manager...
Page 118: ...106 IBM Netfinity 4500R User s Reference Input Output ports...
Page 192: ...180 IBM Netfinity 4500R User s Reference...
Page 196: ...184 IBM Netfinity 4500R User s Reference...
Page 197: ......