Chapter 7. Solving problems
117
11xx
An error occurred during the system-board serial port test.
Action:
If you have a modem, serial printer, or other serial device attached to your
server, verify that the serial cable is connected correctly. If it is, use the
following procedure:
1. Turn off the server.
2. Disconnect the serial cable from the serial port.
3. Wait five seconds; then, turn on the server.
If the POST error message does not reappear, either the serial cable or the device is
probably failing. See the documentation that comes with the serial device for additional
testing information.
If the POST error message reappears, call for service.
1162
The serial port configuration conflicts with another device in the system.
Action:
1. Make sure the IRQ and I/O port assignments needed by the serial port
are available.
2. If all interrupts are being used by adapters, you might need to remove
an adapter to make an interrupt available to the serial port, or force
other adapters to share an interrupt.
1301
Cable to Information LED panel not detected.
Action:
Make sure that the cable to the operator information panel is connected.
If the problem persists, call for service.
1302
Cable to Power and Reset pushbuttons not detected.
Action:
Make sure that the cable to the Power and Reset pushbuttons is connected.
If the problem persists, call for service.
1303
I2C cable to Power Backplane not detected.
Action:
Make sure that the cable to the power backplane is connected.
If the problem persists, call for service.
1304
Cable to Diagnostic LED panel not detected.
Action:
Make sure that the cable to the diagnostic LED panel is connected.
If the problem persists, call for service.
1600
The Netfinity Advanced System Management processor is not functioning.
Action:
1. Verify that the jumpers for the system-management processor are set
correctly.
2. Disconnect the server from all electrical sources, wait for 30 seconds,
reconnect the server to the electrical sources, and restart the server.
If the problem persists, call for service.
1601
The BIOS needs to be updated.
Action:
1. Disconnect the server from all electrical sources, wait for 30 seconds,
reconnect the server to the electrical sources, and restart the server.
2. If the problem persists, update the BIOS.
If the problem persists, call for service.
POST message
Description
Table 15. POST error messages
Summary of Contents for Netfinity 4500R
Page 1: ...IBM IBM Netfinity 4500R User s Reference SC19 K080 60...
Page 2: ......
Page 3: ...IBM IBM Netfinity 4500R User s Reference SC19 K080 60...
Page 10: ...viii IBM Netfinity 4500R User s Reference Safety...
Page 32: ...20 IBM Netfinity 4500R User s Reference Using the SCSISelect utility program...
Page 70: ...58 IBM Netfinity 4500R User s Reference Netfinity Manager...
Page 118: ...106 IBM Netfinity 4500R User s Reference Input Output ports...
Page 192: ...180 IBM Netfinity 4500R User s Reference...
Page 196: ...184 IBM Netfinity 4500R User s Reference...
Page 197: ......