Message 9–E:
Reserved.
Message F–Status Not As Required:
Occurs when one of the following byte 8
Reason Codes is specified.
Code Reason
00 No
message.
01–28 Reserved.
29
Trying to do a Perform Subsystem Function command with the Set
Special Intercept Condition order on an interface on which no path group
has been established.
2A–2E Reserved.
2F
A command was chained from a Reset Allegiance command that was
unsuccessful.
30
A command chained from a Sense command that bypassed device busy
encounters the device busy condition.
31–33 Reserved.
34
Interface ID not valid for receiving control unit.
35–45 Reserved.
46
Attempt to Set System Characteristics on a path that does not have a
path group established.
47–48 Reserved.
49
A command other than Sense ID, Read Device Characteristics, Read
Configuration Data, Sense Subsystem Status was received on a device
that was busy and the I/O was started with either a Sense ID, Read
Device Characteristics, Read Configuration Data, or a Sense Subsystem
Status Command.
50–7F Reserved.
80
Trying to do a specific command on an interface that was disabled for
specific commands by the Perform Subsystem Function command with
the Set Special Intercept Condition order. See "Set Special Intercept
Condition x'1B'" on page 4-112.
81
An attention was presented on an interface that was disabled for specific
commands by a Perform Subsystem Function command with a Set
Special Intercept Condition order. See "Set Special Intercept Condition
x'1B'" on page 4-112.
82–FF Reserved
Format 1–Device Equipment Checks
Format 1 is used to report there are physical device errors or that intervention is
required. The bits 0-3 of byte 7 are set to b'0001' to indicate format 1.
This format is to used to report the following exceptions for an emulated 3380
logical volume:
Device fails to respond, message 0
Predictive failure analysis, message 1
Chapter 5. 24-Byte Compatibility Sense Data
5-11
Summary of Contents for Multiprise 3000
Page 2: ......
Page 3: ...S 390 IBM Internal Disk Subsystem Reference Guide SA22 1025 00 ...
Page 32: ...2 12 Internal Disk Subsystem Reference Guide ...
Page 38: ...3 6 Internal Disk Subsystem Reference Guide ...
Page 182: ...4 144 Internal Disk Subsystem Reference Guide ...
Page 198: ...5 16 Internal Disk Subsystem Reference Guide ...
Page 214: ...6 16 Internal Disk Subsystem Reference Guide ...
Page 234: ...A 10 Internal Disk Subsystem Reference Guide ...
Page 238: ...B 4 Internal Disk Subsystem Reference Guide ...
Page 243: ...4 lease the Code or any copy of it Appendix C Warranties C 5 ...
Page 244: ...C 6 Internal Disk Subsystem Reference Guide ...
Page 248: ...D 4 Internal Disk Subsystem Reference Guide ...
Page 254: ...X 6 Internal Disk Subsystem Reference Guide ...
Page 263: ......