rejected with unit check status. The sense data contains command reject with
format 0, message 2.
Ending Status:
When the parameters have been validated, channel end and
device end are presented.
Sense Subsystem Status
The Sense Subsystem Status command causes the Internal Disk to send 40 bytes
of information to the channel describing the status of the Internal Disk and the
addressed logical volume. If the CCW count is more than 40, only 40 bytes are
transferred. If the CCW count is fewer than 40 bytes, only the specified number of
bytes transfer. The information describes the status of the Internal Disk subsystem
and the addressed logical volume.
This command is accepted even if the logical volume is not ready. See “Effect of
Subsystem and Device State on Status Presented to Command” on page 2-5 for
the operation of this command when other subsystem and device status conditions
occur.
Chaining and Restrictions
Unit check status with the sense data containing
command reject with format 0, message 2 occurs if:
This command is in the domain of a Locate Record or Locate Record
Extended.
This command is not the first command in the chain or it is not chained directly
from a:
– Read Device Characteristics command
– Read Configuration Data command
– Suspend Multipath Reconnection command that was the first command in
the chain.
Ending Status:
Channel end and device end occurs when data transfer is
complete.
If any command is chained from the Sense Subsystem Status command, that
command is rejected with unit check status. The sense data contains command
reject with format 0, message 2. This command reject does not affect the
operation of the Sense Subsystem Status command.
The subsystem status bytes are shown in Table 4-38 on page 4-137.
Hex Code
Data Address
Count
54
The main storage location for the first byte of status.
40
4-136
Internal Disk Subsystem Reference Guide
Summary of Contents for Multiprise 3000
Page 2: ......
Page 3: ...S 390 IBM Internal Disk Subsystem Reference Guide SA22 1025 00 ...
Page 32: ...2 12 Internal Disk Subsystem Reference Guide ...
Page 38: ...3 6 Internal Disk Subsystem Reference Guide ...
Page 182: ...4 144 Internal Disk Subsystem Reference Guide ...
Page 198: ...5 16 Internal Disk Subsystem Reference Guide ...
Page 214: ...6 16 Internal Disk Subsystem Reference Guide ...
Page 234: ...A 10 Internal Disk Subsystem Reference Guide ...
Page 238: ...B 4 Internal Disk Subsystem Reference Guide ...
Page 243: ...4 lease the Code or any copy of it Appendix C Warranties C 5 ...
Page 244: ...C 6 Internal Disk Subsystem Reference Guide ...
Page 248: ...D 4 Internal Disk Subsystem Reference Guide ...
Page 254: ...X 6 Internal Disk Subsystem Reference Guide ...
Page 263: ......