Chapter 7. Field replaceable units
This chapter describes the removal of field-replaceable server components.
Important:
The field replaceable unit (FRU) procedures are intended for trained
servicers who are familiar with IBM products. See the parts listing in
“System” on page 94 to determine if the component being replaced is a
customer replaceable unit (CRU) or a FRU.
Microprocessor removal
Note:
v
Read “Installation guidelines” on page 27.
v
Read the safety notices at Appendix B, “Safety information,” on page 97.
v
Read “Handling static-sensitive devices” on page 27.
Complete the following steps to remove a microprocessor:
1. Shut down the operating system, turn off the blade server, and remove the
blade server from the BladeCenter unit (see “Removing the blade server from
the BladeCenter unit” on page 29).
2. Carefully lay the blade server on a flat, non-conductive surface.
3. Open the blade server cover (see “Opening the blade server cover” on page 34
for instructions).
4. Remove the bezel assembly (see “Removing the blade server bezel assembly”
on page 36 for instructions).
5. Identify the microprocessor to be removed.
Note:
If you are replacing a failed microprocessor, verify that you have selected
the correct microprocessor for replacement (see “Light path diagnostics”
on page 75).
6. Remove the heat sink:
a. Loosen one captive screw fully; then, loosen the other captive screw.
Attention:
Loosening one screw fully before loosening the other screw will
help to break the thermal bond that adheres the heat sink to the
microprocessor.
b. Gently pull the heat sink off of the microprocessor.
7. Rotate the locking lever on the microprocessor socket from its closed and
locked position until it stops or clicks in the fully open position (approximately
135° angle), as shown in Figure 28 on page 58.
© Copyright IBM Corp. 2003
57
Summary of Contents for eServer BladeCenter HS20 Type 8832
Page 1: ...BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 2: ......
Page 3: ...BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 6: ...iv BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 10: ...viii BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 18: ...8 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 64: ...54 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 66: ...56 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 118: ...108 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 119: ...Appendix B Safety information 109 ...
Page 120: ...110 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 121: ...Appendix B Safety information 111 ...
Page 122: ...112 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 123: ...Appendix B Safety information 113 ...
Page 124: ...114 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 136: ...126 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 137: ...Appendix B Safety information 127 ...
Page 138: ...128 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 139: ...Appendix B Safety information 129 ...
Page 140: ...130 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 141: ...Appendix B Safety information 131 ...
Page 146: ...136 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 152: ...142 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 156: ...146 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 157: ......
Page 158: ... Part Number 49Y0165 Printed in USA 1P P N 49Y0165 ...