Figure 51. PuTTY tool
d. Power on IBM Elastic Storage System 3200 canister 1 (left). You must press the power button to
boot the system up (see Figure 17 on page 42). The system begins to boot and directs to a login
prompt.
Note: If you are greeted with the BMC login prompt vs the OS login prompt login to the BMC with
the following credentials:
UserID: sysadmin
Password: <{Enclosure serial number}A|B>
If you cannot log in to the BMC, either the canister might be an FRU replacement or there might be
an issue in manufacturing. Log in by using the default manufacturing password, that is, superuser.
Once logged in, run the following command to fix the console redirection:
ipmitool -I lanplus -H 127.0.0.1 -U admin -P <{Enclosure serial number}A|B> raw 0x3c 0xcc 0x0
You should immediately be greeted with the O/S login prompt. If not you need to power cycle the
canister.
If you do not see the O/S login prompt immediately, the canister might not be powered on. Run
the following command to confirm the chassis power status:
ipmitool -I lanplus -H 127.0.0.1 -U admin -P <{Enclosure serial number}A|B> chassis
power status
If the chassis power state is off, run the following command to boot the canister:
ipmitool -I lanplus -H 127.0.0.1 -U admin -P <{Enclosure serial number}A|B> chassis
power on
Approximately in 5 minutes, the node is booted with an O/S login prompt.
Log in only as sysadmin to fix the serial redirection issue if needed. If the system boots to the OS
login prompt, skip this step.
66 IBM Elastic Storage System 3200: Hardware Planning and Installation Guide
Summary of Contents for Elastic Storage System 3200
Page 6: ...vi ...
Page 11: ...99 Adapter slot to access server via Ethernet 121 xi ...
Page 12: ...xii ...
Page 18: ...xviii IBM Elastic Storage System 3200 Hardware Planning and Installation Guide ...
Page 42: ...24 IBM Elastic Storage System 3200 Hardware Planning and Installation Guide ...
Page 100: ...82 IBM Elastic Storage System 3200 Hardware Planning and Installation Guide ...
Page 108: ...90 IBM Elastic Storage System 3200 Hardware Planning and Installation Guide ...
Page 132: ...114 IBM Elastic Storage System 3200 Hardware Planning and Installation Guide ...
Page 136: ...118 IBM Elastic Storage System 3200 Hardware Planning and Installation Guide ...
Page 140: ...122 IBM Elastic Storage System 3200 Hardware Planning and Installation Guide ...
Page 142: ...124 IBM Elastic Storage System 3200 Hardware Planning and Installation Guide ...
Page 150: ...132 IBM Elastic Storage System 3200 Hardware Planning and Installation Guide ...
Page 155: ......
Page 156: ...IBM Product Number 5765 DME 5765 DAE SC31 5733 00 ...