v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
I9990305
An
operating
system
was
not
found.
1.
Make
sure
that
a
bootable
operating
system
is
installed.
2.
Run
the
hard
disk
drive
diagnostic
tests
(see
the
Problem
Determination
and
Service
Guide
for
information
about
running
the
diagnostic
tests).
3.
Reseat
the
following
components:
a.
Hard
disk
drive
cable
b.
Hard
disk
drive.
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
Hard
disk
drive
cable
b.
Hard
disk
drive
c.
(Trained
service
technician
only)
System
board
19990650
The
ac
power
has
been
restored.
1.
Reseat
the
power
cord.
2.
Check
for
the
interruption
of
external
power
source.
3.
Replace
the
power
cord.
Chapter
5.
Solving
problems
45
Summary of Contents for E Server x 100 Series
Page 3: ...xSeries 100 Type 8486 Installation Guide ERserver...
Page 40: ...28 xSeries 100 Type 8486 Installation Guide...
Page 46: ...34 xSeries 100 Type 8486 Installation Guide...
Page 50: ...38 xSeries 100 Type 8486 Installation Guide...
Page 84: ...72 xSeries 100 Type 8486 Installation Guide...
Page 85: ......
Page 86: ...Part Number 31R2068 Printed in USA 1P P N 31R2068...