CAUTION:
Ensure that the building power circuit breakers are turned off BEFORE you
connect the power cord or cords to the building power. (C023)
CAUTION:
To reduce the risk of electrical shock or energy hazards:
v
This equipment must be installed by trained service personnel in a
restricted access location, as defined by NEC and IEC 60950, The Standard
for Safety of Information Technology Equipment.
v
Connect the equipment to a reliably grounded, safety extra low voltage
(SELV) source. A SELV source is a secondary circuit that is designed so
that normal and single fault conditions do not cause the voltages to exceed
a safe level (60 volts DC).
v
The branch circuit overcurrent protection must be rated per the following
table.
v
Use copper wire conductor only, not exceeding 3 m (9.8 ft.) in length and
sized according to the following table.
v
Torque the wiring-terminal screws to the values in the following table.
v
Incorporate a readily available approved and rated disconnect device in the
field wiring.
(C033)
Table 2. Power specifications
Power
Specification
Circuit breaker rating
Minimum and maximum: 20 amps
Wire size
v
16 AWG DC power cable from PDP output
to server input)
v
1.31 mm2
Wiring terminal screw torque
v
inch pounds
v
newton meters
Each power supply can be connected to a separate DC power source to mitigate
the risk of down time during a power failure. When used in a redundant
configuration, the dual power supplies have a load-sharing capability that allows
each supply to operate at approximately 50 percent of full load. Using redundant
power can minimize the power disruption during a power supply failure and extend
the expected lifetime of each supply by operating normally in a conservative power
mode.
There is no power switch on the RackSwitch; the switch unit powers up when
power is supplied through the DC power source.
The Power Supply LED indicates the status of the power supplies. The LED flashes
when only one DC power source is connected, and is steady when both DC power
sources are connected.
Note:
DC power is not available for the RackSwitch G8124-E.
Chapter 1. Introduction
7
Summary of Contents for BNT RackSwitch G8124
Page 1: ...IBM System Networking RackSwitch G8124 and G8124 E Installation Guide...
Page 2: ......
Page 3: ...IBM System Networking RackSwitch G8124 and G8124 E Installation Guide...
Page 7: ...DANGER Rack mounted devices are not to be used as shelves or work spaces L002 Safety v...
Page 9: ...Safety vii...
Page 14: ...xii IBM System Networking RackSwitch G8124 and G8124 E Installation Guide...
Page 64: ...48 IBM System Networking RackSwitch G8124 and G8124 E Installation Guide...
Page 72: ...56 IBM System Networking RackSwitch G8124 and G8124 E Installation Guide...
Page 76: ...60 IBM System Networking RackSwitch G8124 and G8124 E Installation Guide...
Page 84: ...68 IBM System Networking RackSwitch G8124 and G8124 E Installation Guide...
Page 87: ......
Page 88: ...Part Number 00AY390 Printed in USA 1P P N 00AY390...