Table
2-1 (Page 22 of 25). POST and Diagnostics Index for
Symptoms, Messages, Error Codes, or Beeps
Symptoms, Messages, Error
Codes, or Beeps
Action/FRU
305 - System board
non-replaceable fuse can be
blown by a defective keyboard,
keyboard cable, or mouse. If you
suspect one of these FRUs,
replace it when you replace the
system board.
“Keyboard” on page 2-40.
Keyboard
Keyboard connection/cable
Mouse
Access Station host card
Access Station client card
System Board
Access Station cable
3XX - Keyboard error.
“Keyboard” on page 2-40.
Keyboard connection
Keyboard
Access Station host card
Access Station client card
Access Station cable
System Board
6XX - Diskette drive error.
“Factory-Installed Drive Devices” on
page 2-47.
Diskette drive connection/cable
Diskette drive
Access Station host card
Access Station client card
Access Station cable
System Board
762 - Math coprocessor error.
“Diagnostics Device Presence Test” on
page 2-43.
Upgrade processor (check Setup Utility,
and system board settings).
System Board
962 - Parallel port conflict.
Test using a wrap plug while running
Diagnostics.
“Diagnostics Device Presence Test” on
page 2-43
Parallel port
System Board
Check Procedures
2-31
All manuals and user guides at all-guides.com
Summary of Contents for Aptiva 2159
Page 2: ...All manuals and user guides at all guides com...
Page 22: ...xx All manuals and user guides at all guides com...
Page 24: ...xxii All manuals and user guides at all guides com...
Page 124: ...2 72 All manuals and user guides at all guides com...
Page 184: ...5 22 All manuals and user guides at all guides com...
Page 186: ...6 2 All manuals and user guides at all guides com a l l g u i d e s c o m...