Table
2-1 (Page 8 of 25). POST and Diagnostics Index for
Symptoms, Messages, Error Codes, or Beeps
Symptoms, Messages, Error
Codes, or Beeps
Action/FRU
Joystick does not work correctly
(installation is correct—see
above symptom).
1. Disable the joystick in the software
application.
2. Enable the mouse as the input device
in the software application.
3. If the mouse works in the software
application, replace the joystick. If the
symptom remains, replace the Mwave
card or the sound adapter card.
4. If the mouse does not work, check the
software application troubleshooting
information provided by the
manufacturer.
Linear Cylinder Access Test
Failed.
Hard disk drive error.
Hard Disk Drive
Hard Disk Drive Cable
System Board
Logic Function Failed.
CPU Logic test error.
Processor
System Board
Loopback Error
COM Port Test or Parallel Port
error.
A wrap plug must be installed to
successfully complete these
tests.
System Board
Wrap Plug
Machine works but fails to go
into Rapid Resume mode when
configuration is set with Standby
mode enabled or Rapid Resume
mode enabled.
Software application was fully activated
before on/off switch was pushed. Try
operating Rapid Resume from Microsoft
Windows 95 Program Manager panel.
Main Components Failed.
System board error.
System Board
Processor
Memory test cannot run at this
location in memory.
Not enough free memory
available to start the memory
test.
Memory SIMM
System Board
Missing QAPlus/PRO Files(s).
One or more diagnostic support
files are missing.
Diagnostic CD
Check Procedures
2-17
All manuals and user guides at all-guides.com
Summary of Contents for Aptiva 2159
Page 2: ...All manuals and user guides at all guides com...
Page 22: ...xx All manuals and user guides at all guides com...
Page 24: ...xxii All manuals and user guides at all guides com...
Page 124: ...2 72 All manuals and user guides at all guides com...
Page 184: ...5 22 All manuals and user guides at all guides com...
Page 186: ...6 2 All manuals and user guides at all guides com a l l g u i d e s c o m...