10. Turn on the system-board tray (see “Turning on the system-board tray” on
page 22).
11. Make sure that the power-on LED on the system-board tray operator panel is
lit continuously, indicating that the system-board tray is receiving power and is
turned on.
If you have changed the configuration of the system-board tray, you might have to
update the server configuration through the BIOS configuration utility program (see
“Updating the server configuration” on page 47).
Reinstalling a 3U chassis in an iDataPlex rack
Statement 4:
≥
18 kg (39.7 lb)
≥
32 kg (70.5 lb)
≥
55 kg (121.2 lb)
CAUTION:
Use safe practices when lifting.
To reinstall a 3U chassis in an iDataPlex rack, complete the following steps:
1. Align the 3U chassis with the rails on the iDataPlex rack; then, slide the 3U
chassis into the rack until it is fully seated.
2. Install the M6 screws that secure the chassis to the rack.
3. Install the hard disk drives (see “Installing a hard disk drive” on page 37).
4. Reconnect the cables on the front of the system-board tray.
5. Turn on the system-board tray (see “Turning on the system-board tray” on page
22).