Table 27. T&D Error Messages and Action (continued)
Error Message
Description
Action
TD 12 FRU 0 X
AFTA Failure
1. See “Standard AFTA Service Check
and Adjustment” on page 285.
2. Replace the logic board.
See “Logic Board - Model A00” on
page 370.
TD 14 FRU 0 20
Thermal Sense Failure
1. Replace the printhead.
See “Printhead” on page 356.
2. Replace the logic board.
See “Logic Board - Model A00” on
page 370.
3. Install new printhead cables.
TD 19 FRU 1 X
Operator Panel Failure
1. This error can occur if the cover is
not opened or closed in less than
10 seconds. Run T&D19 again to
verify the problem.
2. See “MAP 0180: Top Cover
Interlock” on page 98.
Chapter 2. Diagnostics