Threshold values written in NVRAM display:
Cx1 Fx2 Rx3(x4)
where:
v
x1 is the threshold for manual path
v
x2 is the threshold for front path
v
x3 is the threshold for rear path and rollers closed
v
x4 is the threshold for rear path and rollers open
v
x1, x2, x3, x4 are numbers in hexadecimal format corresponding to the threshold voltages with resolution
of 20 mV.
Press the Micro
↓
key to go to step 7.
7. The following displays:
Y SENSOR LEVEL N
This part of the test is intended for use by Product Engineering. It allows the user to examine sensor output
voltages.
8. Press the Load/Form Feed key to skip to step 9.
Press the Micro
↑
key to enter.
The current sensor measurements display:
C:x1 F:x2 R:x3
where:
v
x1 is manual path measurement
v
x2 is front path measurement
v
x3 is rear path measurement
Chapter 2. Diagnostics
188