Table 17. Model A00 Error Messages (continued)
Message
Description
Action
JUMPER AND KEYS
Manufacturing use only.
1.
Remove the jumper from the bottom of
the operator panel.
2.
Install a new EMI filter assembly (used
only with early-level logic boards). See
“EMI Filter (Model A00 Early-Level
Logic Board Only)” on page 377.
3.
Install a new operator panel. See
“Operator Panel” on page 355.
4.
Install a new operator panel cable.
5.
Install a new logic board. See “Logic
Board - Model A00” on page 370.
Reference Table 2, Models 001, 002, and 003 Error Messages
Table 18. Error Messages for Models 001, 002, and 003
Message
Description
Action
001 END OF FORMS
Forms do not load when Load/Eject is
pressed.
No forms movement.
See “MAP 0130: No Paper Movement” on
page 62.
001 END OF FORMS
Forms are visible between the printhead
and the platen.
Forms path sensor cannot sense paper.
See “MAP 0131: Paper Path Sensor” on
page 66.
002 FORMS JAMMED FRONT TRACTOR
CLEAR JAM AND RELOAD FORMS
Jam detected at the front tractor sensor.
See “MAP 0190: Form Feed Problems” on
page 101.
005 MARGIN ERROR
ADJUST MARGIN OR LINE LENGTH
Left margin incorrect.
Press Stop, then Start. Left margin value
will be reset to 10 for current line only.
Chapter 1. Diagnosing Problems
136
Summary of Contents for 4247
Page 1: ...4247 Printers Maintenance Information Document Number SA24 4400 05 Part Number 27P8450 IBM ...
Page 241: ...e90apc15 Figure 24 Main Input Power Supply Ground Chapter 3 Circuit Diagrams 241 ...
Page 257: ...Figure 32 Stacker Motor Wiring Chapter 3 Circuit Diagrams 257 ...
Page 261: ...Stacker Cable Wiring Figure 36 Tractor Assembly Cable Wiring Chapter 3 Circuit Diagrams 261 ...