MAP 0200: 55 AFTA errors
Symptom explanation
Suspected FRUs/causes
055 MACHINE CHECK
The AFTA sensor circuit did not detect that needle 5B moved at the
correct time during the AFTA routine. The needle either failed to
extend or was not detected when it was pushed back.
Printhead misaligned and loosely fastened
AFTA motor defective
22-conductor printhead cable damaged or poor connection
Mechanical parts damaged or binding
Printhead defective
Logic board defective
!
CAUTION:
The printhead may be hot. Wait for it to cool down.
Table 15. MAP 0200: 55 AFTA errors
Step
Questions/Actions
Yes
No
1.
Perform the Standard AFTA Service Check (see Standard
AFTA service check and adjustment).
Is the service check OK?
Go to step 2.
Repair as needed.
Mount forms, and try loading
and parking forms several
times.
Run T&D in automatic test
mode to verify correct printer
operation (see Running the
test and diagnostic (T&D)
programs).
Chapter 1. Diagnosing problems
73
Summary of Contents for 4247-V03
Page 24: ...Reference table 8 ribbon lift and 26 pin cable connectors 93 Chapter 1 Diagnosing problems 24 ...
Page 138: ...Operator panel cable wiring Chapter 3 Wiring diagrams 138 ...
Page 144: ...Tractor assembly cable wiring Chapter 3 Wiring diagrams 144 ...
Page 164: ...Chapter 5 Removals service checks and adjustments 164 ...
Page 173: ...Table 24 Print quality sample 1 2 3 Chapter 5 Removals service checks and adjustments 173 ...
Page 246: ...Assemblies Chapter 6 Parts catalog 246 ...
Page 307: ...Taiwanese EMC Notices 307 ...
Page 310: ...Index Copyright IBM Corp 2002 310 ...
Page 311: ...IBMR Part Number 75P1301 Printed in U S A G544 5873 00 1P P N 75P1301 ...