T&D error messages and actions
Table 20. T&D error messages and actions
Error Message
Description
Action
ERROR RAM
TEST
RAM error
Replace the logic board (see Logic board).
ATTACHMENT
CARD IS NOT
COMPATIBLE
WITH PRINTER
BASE CODE
Coax card error
Verify that the coax card is installed with the coax base
code.
WAITING CODE
DOWNLOAD
USING PARALLEL
PORT
Operator error
Verify that you are using the Stop and Test keys at
power on to initiate test and diagnostics
TD 1 FRU 5
X
- or -
TD 1 FRU 4
X
Microcode/Hardware
Match Error
Replace the logic board (see Logic board.
TD 1 FRU 2 2
Microcode error
Replace the logic board (see Logic board.
TD 2 FRU 1 X
Operator panel
failure
1. This error can occur if a key is not pressed in less
than 10 seconds. Run T&D02 again to verify the
problem.
2. Replace the operator panel (see Operator panel.
3. Replace the logic board (see Logic board).
4. Replace the operator panel cable.
TD 3 FRU 0 X (*)
Parallel interface
failure
Replace the logic board (see Logic board).
TD 4 FRU 0 X
Microcode error
Replace the logic board (see Logic board).
TD 08 FRU 0 X
AFTA failure
1. See Standard AFTA service check and adjustment.
2. Replace the logic board (see Logic board).
Chapter 2. Diagnostics
127
Summary of Contents for 4247-V03
Page 24: ...Reference table 8 ribbon lift and 26 pin cable connectors 93 Chapter 1 Diagnosing problems 24 ...
Page 138: ...Operator panel cable wiring Chapter 3 Wiring diagrams 138 ...
Page 144: ...Tractor assembly cable wiring Chapter 3 Wiring diagrams 144 ...
Page 164: ...Chapter 5 Removals service checks and adjustments 164 ...
Page 173: ...Table 24 Print quality sample 1 2 3 Chapter 5 Removals service checks and adjustments 173 ...
Page 246: ...Assemblies Chapter 6 Parts catalog 246 ...
Page 307: ...Taiwanese EMC Notices 307 ...
Page 310: ...Index Copyright IBM Corp 2002 310 ...
Page 311: ...IBMR Part Number 75P1301 Printed in U S A G544 5873 00 1P P N 75P1301 ...