PCNTNW-DOS-29 WARNING: DMA number is not
necessary for PCI device.
Explanation: The Ethernet controller does not require a
DMA setting.
Action: Remove the DMA setting in PROTOCOL.INI.
PCNTNW-DOS-32 IRQ number is already in use by
another PCNET device.
Explanation: The specified IRQ number is already in use
by another Ethernet controller or device.
Action: Modify the IRQ setting in the PROTOCOL.INI file,
or modify the IRQ settings in the configuration programs.
See “Resolving Hardware Configuration Conflicts” on
page 77 for information on setting the interrupt requests in
the configuration programs.
PCNTNW-DOS-33 PCNET device with specified
IOBASE is already in use.
Explanation: The specified IO address number is already
in use by another Ethernet controller or device.
Action: Modify the IO address setting on the hardware,
or modify the IO address setting in the PROTOCOL.INI
file.
PC Server 315 - Type 8638
43