Table 3 – Troubleshooting Procedures - cont…
6. Control does not draw
brine.
a. Low water pressure
b. Restricted drain line.
c. Injector or injector screen plugged.
!
d. Injector defective.
!
e. Valve general malfunction
f. Air check prematurely closed in
brine tank
a. Increase water pressure (330kpa)
b. Remove restriction.
c. Clean injector and screen, Refer to the
Cleaning the Injector/Injector Screen
section in this manual.
d. Replace injector. Contact dealer.
e. Contact dealer
f. Replace or repair air check if needed.
Check brine line connections.
7. Intermittent or irregular
brine draw.
a. Low water pressure.
b. Defective injector.
!
a. Increase water pressure.
b. Replace both injector and injector cap.
Contact dealer.
8. Brine tank overflow.
a. Air leak in brine line to air check.
b. Refill control incorrect.
a. Check all connections in brine line for
leaks.
b. Replace with correct controller
9. System using more or
less salt than estimated.
a. Inaccurate program setting of brine
refill.
b. Air check system incorrect.
c. Defective brine refill operation
control
a. Contact dealer.
b. Contact dealer.
c. Contact dealer.
10. Control backwashes at
excessively low or high
rate.
a. Incorrect backwash controller.
b. Foreign matter affecting controller
operation. !
a. Contact dealer.
b. Remove backwash controller. Clean &
replace.
11. Flowing or dripping water
at drain line after
regeneration.
a. Internal valve malfunction.
a. Contact dealer.
Summary of Contents for AST1041TC-CL
Page 3: ...AS1041TC CL Page 3...
Page 7: ...AS1041TC CL Page 7 Note Maximum number of days that can be selected is 99...
Page 23: ...AS1041TC CL Page 23 SPARE PARTS AND SERVICING INSTRUCTIONS...
Page 32: ...AS1041TC CL Page 32 flow diagram backwash Flow Diagram Down flow Brine...
Page 33: ...AS1041TC CL Page 33 flow diagram downflow brine Flow Diagrams Rinse and Fill...
Page 34: ...AS1041TC CL Page 34 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01...
Page 41: ...AS1041TC CL Page 41...