Power outage
When electric power is interrupted the microprocessor will hold all relevant information in memory
except for
the
current time of day.
Current time of day
When power is restored the display will Flash and go to the Time-Hour Setting. Press
SET HOUR
and input
the current Time OF Day
. If power is lost during a regeneration cycle the valve will remain operational
in the current cycle and will recommence electrically in that cycle when power is restored.
In long power outages it is advisable to check that the system is not in a regeneration cycle that could
be discharging water to drain and in this instance it would be advisable to place the valve in bypass
mode until power is restored.
General
Note: When changing valve operational cycles the valve control will emit a number of whirring sounds.
Note :- The valve cannot be positioned into the regeneration mode without ELECTRIC Power.
USER DISPLAYS.
General Operation
When the system is operating one or two displays will be shown. Pressing
the UP or DOWN button will alternate between the displays. One of the
displays is the Current Time of Day to the nearest HOUR and the second
Display is the days remaining until the next regeneration. If the days
remaining is equal to ONE then regeneration will take place at the next
preset regeneration time. The user can scroll between the displays as
desired.
If the system has called for a regeneration at the preset time then an
arrow will point to “
Regen.“
on the panel face.
Regeneration Mode
Typically a softener is set to regenerate at a time of NO or low water
usage. Factory default is
2 am
. If there is a demand for water when the
system is regenerating then Hard water only will be available. If a system
demands that no hard water is bypassed during regeneration , then the
softener will have to have a Hard Water Bypass Prevention Solenoid
Valve fitted.
When the system begins to regenerate, the display will change to
indicate the various cycles of the regeneration process C1>C5 and an
arrow will point to Regen. The system will automatically step through the
regeneration cycles and reset back to the service cycle when the
regeneration is complete.
Manual Regeneration
A manual regeneration can be initiated in two ways.
Delayed or
Immediate.
For Delayed at the preset time of regeneration:
Simultaneously Press
▲▼
buttons
together and release. An arrow will appear next to
Regen.
This request can be cancelled if necessary by again
simultaneously pressing the
▲▼
buttons together.
For Immediate regeneration:
Simultaneously Press
▲▼
buttons
together for about 5 seconds until the valve changes to the C1 mode.
The softener will begin to regenerate immediately .
This request cannot
be cancelled.
Summary of Contents for AST1041TC-CL
Page 3: ...AS1041TC CL Page 3...
Page 7: ...AS1041TC CL Page 7 Note Maximum number of days that can be selected is 99...
Page 23: ...AS1041TC CL Page 23 SPARE PARTS AND SERVICING INSTRUCTIONS...
Page 32: ...AS1041TC CL Page 32 flow diagram backwash Flow Diagram Down flow Brine...
Page 33: ...AS1041TC CL Page 33 flow diagram downflow brine Flow Diagrams Rinse and Fill...
Page 34: ...AS1041TC CL Page 34 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01...
Page 41: ...AS1041TC CL Page 41...