AS1041TC-CL
Page
18
Brine Line Connection
The brine line comprises a pick up air check
assembly installed in the brine wall in the cabinet and
connected by tubing to the brine elbow on top of the
valve.
Note:
Make sure that all fittings and connections are
tight so that premature checking does not take place.
Premature checking occurs when the ball in the air
check seals before all brine is drawn out of the brine
tank. Refer to the
Troubleshooting
section in this
manual for additional information.
Brine Tank Overflow Line Connection
In the event of a malfunction, the tank overflow
connection directs overflow to the drain instead of
spilling on the floor where it could cause water
damage. Complete the following steps to connect the
overflow fitting to the brine tank:
1. Locate the fitting overflow on the side of the brine
tank.
2. Attach a length of 1/2in (1.3cm) tubing (not
supplied) to the fitting and run to the drain.
Note:
Do not elevate the overflow line higher than
80mm below the bottom of the overflow fitting. Do not
tie into the drain line of the control unit. The overflow
line must be a direct, separate line from the overflow
fitting to the drain, sewer or tube. Allow an air gap as
in the drain line connection.
Overflow Line Connection
Summary of Contents for AST1041TC-CL
Page 3: ...AS1041TC CL Page 3...
Page 7: ...AS1041TC CL Page 7 Note Maximum number of days that can be selected is 99...
Page 23: ...AS1041TC CL Page 23 SPARE PARTS AND SERVICING INSTRUCTIONS...
Page 32: ...AS1041TC CL Page 32 flow diagram backwash Flow Diagram Down flow Brine...
Page 33: ...AS1041TC CL Page 33 flow diagram downflow brine Flow Diagrams Rinse and Fill...
Page 34: ...AS1041TC CL Page 34 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01...
Page 41: ...AS1041TC CL Page 41...