Inlet/Outlet Fittings
25mm BSPF PVC elbows
Cycles
6
Valve Material
Noryl (1) or equivalent
Regeneration
Down flow
FLOW RATES
Service @15psi/1 bar drop (includes bypass & meter)
102 lpm
Backwash @25psi/1.7 bar drop (includes bypass)
102 lpm
OPERATING PRESSURE
Minimum/Maximum
330-600 kpa (48-100 psi)
OPERATING TEMPERATURE
5°C---43°C
DIMENSIONS & WEIGHT
Distributor Pilot
1.050” OD Pipe (3/4” NPS)
Drain Line
½” (12mm) Hose Tail
Brine Line
3/8” OD Poly Tube
Mounting Base
2 /12” – 8 NPSM
Height from Top of Tank
7 3/8” (187mm)
Weight
4.5lbs (2kg)
Distributor Pilot
12mm Above Tank Top
ELECTRICAL SPECIFICATIONS
AC Adaptor
Supply Voltage
230V AC
Supply Frequency
50 Hz
Output Voltage
12—16 V AC
Output Current
500 mA
CYCLES OF OPERATION
Factory Set
Minutes
Backwash 1
st
(upflow)
C1
8
Regenerate draw/slow rinse (downflow)
C2
70
Backwash 2
nd
(upflow)
C3
10
Fast Rinse (downflow)
C4
6
*Regenerant Refill (in service with treated water)
C5
17
Service (down flow)
C0
Note C1 to C4 are fixed values and cannot be varied.
C5 will vary to suit model of softener
(Noryl is a trademark of General Electric)
GENERAL” WS1 TC” CONTROL VALVE
SPECIFICATONS
Summary of Contents for AST1041TC-CL
Page 3: ...AS1041TC CL Page 3...
Page 7: ...AS1041TC CL Page 7 Note Maximum number of days that can be selected is 99...
Page 23: ...AS1041TC CL Page 23 SPARE PARTS AND SERVICING INSTRUCTIONS...
Page 32: ...AS1041TC CL Page 32 flow diagram backwash Flow Diagram Down flow Brine...
Page 33: ...AS1041TC CL Page 33 flow diagram downflow brine Flow Diagrams Rinse and Fill...
Page 34: ...AS1041TC CL Page 34 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01...
Page 41: ...AS1041TC CL Page 41...