AS14100MP-CL
Page
17
drop the transformer or have the cable too taut. The
transformer is only suitable for
internal use only
.
For full understanding of the water softener we
recommend that the instruction manual be fully read
before installation and commissioning of the softener
by undertaken.
IMPORTANT:
A
NUMBER
OF
VALVE
COMPONENTS ARE LOCKED INTO POSITION
WITH
EASILY
REMOVABLE
CLIPS
.
ENSURE ALL LOCKING CLIPS ARE CORRECTLY
IN POSITION BEFORE PRESSURISING THE
SOFTENER. ENSURE THAT IT IS POINTED OUT
TO ALL RELEVANT PERSONNEL THAT THE
LOCKING CLIPS MUST NOT BE REMOVED
WHILST THE SYSTEM IS UNDER WATER
PRESSURE.
Note: All electrical connections must be connected
according to local codes.
Install grounding strap on metal plates.
Bypass Valve
The bypass valve is typically used to isolate the
control valve from the plumbing system’s water
pressure in order to perform control valve repairs or
maintenance. The WS1 bypass valve is particularly
unique in the water treatment industry due to its
versatility and state of the art design features. The
full flow bypass valve incorporates four positions,
including a diagnostic position that allows service
personnel to work on a pressurised system while still
providing untreated bypass water to the facility or
residence. Its completely non-metallic, all plastic
design allows for easy access and serviceability
without the need for tools.
The bypass body and rotors are glass filled Noryl (or
equivalent) and the nuts and caps are glass filled
polypropylene. All seals are self-lubricating EPDM to
help prevent valve seizing after long periods of non-
use. Internal o-rings can easily be replaced if service
is required.
The bypass consists of two interchangeable plug
valves that are operated independently by red arrow-
shaped handles. The handles identify the flow
direction of the water. The plug valves enable the
bypass valve to operate in four positions.
1.
Normal Operation Position
: The inlet and outlet
handles point in the direction of flow indicated by
the engraved arrows on the control valve. Water
flows through the control valve during normal
operation and this position also allows the control
valve to isolate the media bed during the
regeneration cycle. (Figure 1)
2.
Bypass Position
: The inlet and outlet handles
point to the centre of the bypass, the control
valve is isolated from the water pressure
contained in the plumbing system. Untreated
water is supplied to the plumbing system. (Figure
2)
3.
Diagnostic Position
: The inlet handle points in
the direction of flow and the outlet handle points
to the centre of bypass valve, system water
pressure is allowed to the control valve and the
plumbing system while not allowing water to exit
from the control valve to the plumbing.(Figure 3)
4.
Shut Off Position:
The inlet handle points to the
centre of the bypass valve and the outlet handle
points in the direction of flow, the water is shut off
to the plumbing system (i.e. plumbing connection
somewhere in the building bypasses the system).
(Figure 4)
Summary of Contents for AS14100MP-CL
Page 3: ...AS14100MP CL Page 3...
Page 10: ...AS14100MP CL Page 10 MODEL AS14100MP WATER SOFTENER WITH CONTROL VALVE SERIES MODEL WS1EI...
Page 18: ...AS14100MP CL Page 18...
Page 19: ...AS14100MP CL Page 19 WS1EI Screen Display Information And Programming Instructions...
Page 21: ...AS14100MP CL Page 21 General Regeneration Error Screens Status...
Page 28: ...AS14100MP CL Page 28 SPARE PARTS AND SERVICING INSTRUCTIONS...
Page 38: ...AS14100MP CL Page 38 flow diagram backwash Flow Diagram Downflow...
Page 39: ...AS14100MP CL Page 39 flow diagram downflow brine Flow Diagrams Rinse and Fill...
Page 40: ...AS14100MP CL Page 40 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01...
Page 48: ...AS14100MP CL Page 48 INJECTOR PERFORMANCE CURVES...
Page 49: ...AS14100MP CL Page 49...
Page 51: ...AS14100MP CL Page 51...