AS14100MP-CL
Page
43
bracket motor retainer. Reconnect the motor plug to the two-pronged jack on the lower left hand side of the PC
board. If the motor will not easily engage with the drive gears when reinstalling, lift and slightly rotate the motor
before reinserting. Reconnect the power plug.
Replace the valve cover. After completing any valve maintenance, press and hold NEXT and REGEN buttons
for 3 seconds or unplug power source jack (black wire) at the circuit board and plug back in. This resets the
electronics and establishes the service piston position. The display should flash all wording, then flash the soft
ware version and then rest the valve to the service position.
Drive Cap Assembly, Main Piston and Regenerant Piston
The drive assembly must be removed to access the drive cap assembly. The drive cap assembly must be
removed to access the piston(s). The drive cap assembly is threaded into the control valve body and seals
with an o-ring. To remove the drive cap assembly use the special plastic wrench or insert a ¼” to ½” flat blade
screwdriver into one of the slots around the top 2” of the drive cap assembly so it engages the notches
moulded into the drive back plate around the top 2” of the piston cavity. The notches are visible through the
holes. Lever the screwdriver so the drive cap assembly turns counter clockwise. Once loosened, unscrew the
drive cap assembly by hand and pull straight out.
The drive cap assembly contains the drive cap, the main drive gear, drive cap spline, piston rod and various other parts that should not be
dissembled in the field. The only replaceable part on the drive cap assembly is the o-ring. Attached to the drive cap assembly is the main piston
(downflow) and if a regenerant is used, a regenerant piston.
The regenerant piston (the small diameter one behind the main piston) is removed from the main piston by
pressing sideways and unsnapping it from its latch. Chemically clean in vinegar, or replace the regenerant
piston if needed. To remove the main downflow or upflow piston fully extend the piston rod and then unsnap
Summary of Contents for AS14100MP-CL
Page 3: ...AS14100MP CL Page 3...
Page 10: ...AS14100MP CL Page 10 MODEL AS14100MP WATER SOFTENER WITH CONTROL VALVE SERIES MODEL WS1EI...
Page 18: ...AS14100MP CL Page 18...
Page 19: ...AS14100MP CL Page 19 WS1EI Screen Display Information And Programming Instructions...
Page 21: ...AS14100MP CL Page 21 General Regeneration Error Screens Status...
Page 28: ...AS14100MP CL Page 28 SPARE PARTS AND SERVICING INSTRUCTIONS...
Page 38: ...AS14100MP CL Page 38 flow diagram backwash Flow Diagram Downflow...
Page 39: ...AS14100MP CL Page 39 flow diagram downflow brine Flow Diagrams Rinse and Fill...
Page 40: ...AS14100MP CL Page 40 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01...
Page 48: ...AS14100MP CL Page 48 INJECTOR PERFORMANCE CURVES...
Page 49: ...AS14100MP CL Page 49...
Page 51: ...AS14100MP CL Page 51...