AS14100MP-CL
Page
7
SUGGESTED SETTINGS
(VOLUME THROUGHPUT IN CUBIC METRES Based on Maximum Exchange Capacity )
TABLE 2
Raw Water Hardness
mg/L CaCO
3
Maximum Program Setting
In Cubic Metres throughput
(see note)
60
115.50
80
87.50
100
70.00
120
57.50
140
50.00
160
43.50
180
38.50
200
35.00
250
28.00
Important Note:
To provide uninterrupted soft water
supply to the end of the service
and just before a regeneration is
due it is strongly recommended to
de-rate the throughput setting by
the average daily usage. Eg. If the
setting is elected at 70.0 then
deduct a figure of one days usage.
(Note:
Estimated
daily
consumption per person is 300
litres or 0.3Cubic Metres :- for 3
people = 0.9 cubic metres :-
deduct One Cubic Metre.)
For Commercial applications it will
be necessary to determine the
daily water usage figure.
For other raw water hardness multiply the throughput at 100 hard i.e.70.0 by the ratio of 100 divided by
the desired hardness.
e.g. for 75 hard
=
70x 100
=
93.3 input 92.5
75
e.g. for 150 hard
=
70x 100
=
46.66 input 46.5
150
Note: The program for M
3
input will only accept the inputting of a whole or half a number. e.g. If the
calculated throughput is say 9.75m
3
then what can be programmed in is 9.5 or 10.0. However, always
select the lower figure i.e. 9.5 in this example. Above 50M³ the program will only accept increments in
2.5 , therefore only input a lower figure eg. Calculation gives 93.3 therefore input 92.5.
Note :- The chart is based on low to medium total dissolved solids water ,consult IBC Water for using the
softener for waters above 250 mg/L hardness.
Programming Parameters to be input at commissioning:
1. Throughput in cubic metres from Table 2.
2. Current time of day.
NOTE: All other parameters have been factory pre-set – DO NOT CHANGE.
MODEL AS14100MP-CL SOFTENER
THE MICROPROCESSOR CONTROL WILL REQUIRE BASIC DATA PROGRAMMING TO SUIT THE
RAW WATER HARDNESS AND DESIRED UNIT CAPACITY
IMPORTANT:
IT IS ESSENTIAL THAT YOU READ THE GENERAL CONDITIONER INFORMATION AND
CONTROL SETTINGS OF THIS MANUAL BEFORE ATTEMPTING TO SET THE FUNCTIONS OF THIS
UNIT. THE DEALER OR AGENT CAN SUPPLY THE RAW WATER HARDNESS
. HOWEVER DO NOT
EXCEED THE MAXIMUM THROUGH PUT IN CUBIC METERS BASED ON THE ACTUAL RAW WATER
HARDNESS FIGURE IN TABLE 2.
Summary of Contents for AS14100MP-CL
Page 3: ...AS14100MP CL Page 3...
Page 10: ...AS14100MP CL Page 10 MODEL AS14100MP WATER SOFTENER WITH CONTROL VALVE SERIES MODEL WS1EI...
Page 18: ...AS14100MP CL Page 18...
Page 19: ...AS14100MP CL Page 19 WS1EI Screen Display Information And Programming Instructions...
Page 21: ...AS14100MP CL Page 21 General Regeneration Error Screens Status...
Page 28: ...AS14100MP CL Page 28 SPARE PARTS AND SERVICING INSTRUCTIONS...
Page 38: ...AS14100MP CL Page 38 flow diagram backwash Flow Diagram Downflow...
Page 39: ...AS14100MP CL Page 39 flow diagram downflow brine Flow Diagrams Rinse and Fill...
Page 40: ...AS14100MP CL Page 40 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01...
Page 48: ...AS14100MP CL Page 48 INJECTOR PERFORMANCE CURVES...
Page 49: ...AS14100MP CL Page 49...
Page 51: ...AS14100MP CL Page 51...