11.3.3.3 Digital signal properties (mode dependent)
– signal MF
The MF channel is only designed for a single ended (“SE”) connection.
Use_MF:
Channel enabled
EnablePullUp_MF:
Only for open collector connection, internal supply (V
cc
= 5 V) 1 kOhm pullup (only
A, B, N) connected
Only for open collector connection,
internal supply (V
cc
= 5 V) 250 Ohm pullup connected
InvertPolarity_MF:
Inverts signal polarity
EnableAnalogFilter_MF:
Enables the analog RC low-pass filter with 180 kHz
FilterMode_MF:
Enables debounce filter
0:
Off (without filter)
1:
Stretch rising edge
2:
Stretch falling edge
3:
Stretch both edges
4:
Delay both edges
FilterTime_MF:
Debounce time of the enabled debounce filter, in
µs [1 µs … 65535 µs]
11.3.3.4 Digital signal properties (mode dependent)
– signal “Dig out”
SafeOutputValue_Dig:
Does not have any function; however, always
needs to be „false“ and has to be
commented in