TECHNICAL DATA
PRESSURE
Maximum pressure
5 bar
Minimum pressure
0.5 bar
TEMPERATURES
Maximum temperature (factory default)
41 °C (can be preset at 46°C)
How water range
55 °C - 65°C
Cold water range
1°C - 20°C
Temperature control
from 15 °C a 46°C
Ambient temperature
1°C - 40°C
Maximum relative humidity
90% non-condensing
FLOW RATE
Maximum fl ow rate (open outlet)
15 L/min @1 BAR outlet 1
15 L/min @1 BAR outlet 2
16 L/min @1 BAR both
ELECTRICAL
Supply voltage
230 V RMS 50Hz ±10%
Maximum load
30W
INSTALLATION, MAINTENANCE AND PRELIMINARY CHECKING PROCEDURE
In
order to get your device work correctly and fi ne in time, must ensure compliance with the mode of installation and
maintenance described in this booklet. Relying on a qualifi ed plumber for the hydric part and on a qualifi ed electrician
for the electrical part. Make sure that the system is free from all debris and impurities existing.
The DIVE remote digital processor must be connected to the DIVE control unit using the supplied cable.
To ensure an optimal water mixing performance, the DIVE control unit must have differential pressure between hot and
cold water not exceeding 0.5 bar.
The DIVE remote digital processor cannot be installed in environments where the temperature drops below 5 °C and rises
above 40 °C. This product is not suitable for high humidity environments, such as a steam room.
The DIVE control unit is factory set at 41 °C MAX, maximum temperature can be reset to 46 °C during confi guration if the
user wishes.
Caution: If the maximum temperature is reset at 46 °C it is at risk for the customer. IB Rubinetti may not
accept liability for any damage caused.
Important: The DIVE Control Unit must be installed in a location that ensures maintenance. The warranty and liability of
IB Rubinetti declines if the position prevents maintenance.
Before completing the installation, pressurize the system and the DIVE control unit, checking for leaks on all pipes and
inlet connections.
After completing the installation, make sure that the user is familiar with the remote control.
These instructions include a user guide, so they should be left behind after installation.
If you do not use the product for a long period of time, empty it out of the water and take out pressure.
Protect the data cables that pass through the wall with a conduit or sheath to allow removal in case of maintenance.
Open DIVE remote control or DIVE control unit, replace or use third party replacement parts, will cause the warranty to
expire.
Read these instructions carefully before using the DIVE system and keep them in a safe place for future reference.
To reduce the risk of injury, apply the necessary precautions for an everyday common appliance.
Do not operate the unit if from the DIVE control unit there is a leak of water.
Do not use if dirty water is entering in the DIVE control unit.
Do not use if the water inside is frozen.
It is important to train children and vulnerable individuals on the proper use of the shower.
Do not use the product if it has been damaged during transport.
When the appliance has reached the end of life, it must be disposed of in accordance with local waste disposal laws.
The DIVE control unit automatically turns off after 15 minutes of operation. At the end of 15 minutes, if you wish, you
can turn on the shower again.