3.1.5 Dispen.TM
(Dispense
Time)
To use group edit to increase all of the dispensing times (Point Dispense Setup) in
memory address range 1 – 200 by 15%:
Instruction Display
Shows
1
Press the
MENU 1
key, then
1
to select
Group Edit
.
The display will prompt the user to enter the starting
memory address of the group to edit (
From
) and
the ending number of the group to edit (
To
).
GROUP EDIT
FROM:1
TO:1
(1 <-> 1000)
2
Type
1
then press
ENTER
to register 1 in
From
.
Type
200
then press
ENTER
to register 200 in
To
.
GROUP EDIT 1-200
1.Copy 4.Line SP
2.Delete 5.Dispen.TM
3.Move 6.Offset
3
The
Group Edit
menu will then appear, allowing the
user to select an operation to be applied to the
range of points.
Press
4
to select
Dispen.TM
.
GROUP DISPENSE TM
Multiple Value:
4
The display will prompt the user to type the Multiple
Value to be applied to the dispense times. For
example, a value of 1.15 will increase all dispense
times by 15%. A value of 0.85 will decrease all
dispense times by 15%.
Type
1.15
and press
ENTER
to select a multiplier
of 1.15.
GROUP DISPENSE TM
Multiple Value:1.15
1.Yes 2.No
SELECT:
5
The display will now prompt the user to confirm the
change. Press
1
to select
Yes
.
All of the Point Dispense Setup instructions in the
select range of points will now be multiplied by
1.15.