I&J7000C Series Operating Manual
Section 5: Point Type & Function Reference
Part # 561978C
Rev. F Dec. 06
- Page
72
-
© 2006 I&J Fisnar Inc.
3.1.4 Line SP (Line Speed)
To use group edit to increase all of the line speed commands in memory address range
1 – 200 by 20 %:
Instruction Display
Shows
1
Press the
MENU 1
key, then
1
to select
Group Edit
.
The display will prompt the user to enter the starting
memory address of the group to edit (
From
) and
the ending number of the group to edit (
To
).
GROUP EDIT
FROM:1
TO:1
(1 <-> 1000)
2
Type
1
then press
ENTER
to register 1 in
From
.
Type
200
then press
ENTER
to register 200 in
To
.
GROUP EDIT 1-200
1.Copy 4.Line SP
2.Delete 5.Dispen.TM
3.Move 6.Offset
3
The
Group Edit
menu will then appear, allowing the
user to select an operation to be applied to the
range of points.
Press
4
to select
Line SP
.
GROUP LINE SP
Multiple Value:
4
The display will prompt the user to type the Multiple
Value to be applied to the line speeds. For
example, a value of 1.2 will increase all speeds by
20%. A value of 0.8 will decrease all speeds by
20%.
Type
1.2
and press
ENTER
to select a multiplier of
1.2.
GROUP LINE SP
Multiple Value:1.2
1.Yes 2.No
SELECT:
5
The display will now prompt the user to confirm the
change. Press
1
to select
Yes
.
All of the line speed instructions in the select range
of points will now be multiplied by 1.2.