I&J7000C Series Operating Manual
Section 5: Point Type & Function Reference
Part # 561978C
Rev. F Dec. 06
- Page
44
-
© 2006 I&J Fisnar Inc.
The instruction at memory address 8 should be changed from End Program to Step &
Repeat X. To register a Step & Repeat X instruction at memory address 8, do the
following:
Instruction Display
Shows
1
Press the
+1
or
–1
keys until memory address 8
is shown in the display
ADDR:8 PROG:20
End Program
2
Press the
Enter
key, then
→
→
→
→
to change to page
2. Select
Step & Repeat X
.
Step & Repeat X
Columns(X):
Rows(Y):
3
Type
4
to specify four columns, then press
ENTER
.
Step & Repeat X
Columns(X):4
Rows(Y):
4
Type
3
to specify three rows, then press
ENTER
.
Columns(X):4
Rows(Y):3
X Offset: (mm)
Y Offset: (mm)
5
In the above example, the X Offset between
parts is 30 mm.
Type
30
to specify an X Offset of 30 mm, then
press
ENTER
.
Columns(X):4
Rows(Y):3
X Offset:30 (mm)
Y Offset: (mm)
6
In the above example, the Y Offset between
parts is 25 mm.
Type
25
to specify 25 mm, then press
ENTER
.
Rows(Y):3
X Offset:30 (mm)
Y Offset:25 (mm)
Start Addr:
7
The display will prompt you for the
Start Addr:
The start address is the memory address of the
first instruction which is part of this Step &
Repeat group. In our example, we want to repeat
all instructions starting with memory address
number 4.
Type
4
to specify memory address 4, then press
ENTER
.
Start Addr:4
1.S Path
2.N Path
Select: