![I&J Fisnar I&J7000C Operating Manual Download Page 13](http://html.mh-extra.com/html/iandj-fisnar/iandj7000c/iandj7000c_operating-manual_601972013.webp)
I&J7000C Series Operating Manual
Section 2: Setup
Part # 561978C
Rev. F Dec. 06
- Page
12
-
© 2006 I&J Fisnar Inc.
3 Setup
The I&J7000C robots are available in many different configurations. The configuration of
each machine and the accessories used with each system will depend on the customer’s
application.
The steps required to setup a system using a 30 cc barrel and a DSP501A dispenser
controller are described below.
3.1.
If the system is being used in the European Community, the robot must be placed in
an enclosure supplied by I&J Fisnar Inc. The enclosure will prevent the operator
from entering the robot’s work area and will generate an emergency stop signal if
the enclosure’s door switch is opened while the robot is running. Connect the
external start / stop box and door switch or light curtain to the Ext. Control connector
on the main unit. For further information, see
SECTION 7:2.1 Ext. Control
Connector
.
If an enclosure is NOT being used, the enclosure door switch can be bypassed
by connecting the plug labeled SHORTED (included in the robot accessories box)
to the Ext. Control Connector.
3.2.
Standard systems are shipped with a
Barrel holder, which must be mounted
on the X/Z head of the robot. The Barrel
Holder will hold a 30 cc or 55 cc barrel
on the robot’s head. An optional Valve
holder may be used as a replacement
for the barrel holder if the application so
requires.
3.3.
Mount the barrel or valve holder on the X/Z axis head as shown, using two hex
screws. The barrel holder has several sets of mounting holes to allow it to be
mounted at four different heights. Choose mounting holes which give maximum
work piece clearance but allow the tip to reach all areas on the work piece where
dispensing is required.
Barrel Holder