56
1. S
pecification
s
Che
c
k
1.2.8 Duty Ratio for Continuous Operation
[Standard Specification]
It can operate continuously when the duty ratio is 100%.
[Standard Specification]
It can operate continuously when the duty ratio is 100%.
[Built-in Controller Specification]
◎
RCP6S-RA4C, 4R
It can operate continuously when the duty ratio is 100%.
◎
RCP6S-RA6C, 6R
Lead 12mm and 20mm can operate continuously when the duty ratio is 100%.
Operate with the duty ratio as in the following graph for lead 3mm and 6mm.
◎
RCP6S-RA7C, 7R
Lead 24mm can operate continuously when the duty ratio is 100%.
Operate with the duty ratio as in the following graph for lead 4mm, 8mm, and 16mm.
◎
RCP6S-RA8C, 8R
Operate with the duty ratio of 70% or less.
Duty ratio is an operating rate, which indicates the time that the actuator is running in one cycle by
percentage.
Duty
ratio(%)
Temperature(°C)
Lead 3mm
Lead 6mm
38°C
Duty
ratio(%)
Temperaturere(°C)
Lead 4mm
Lead 8mm
37°C
35°C
Lead 16mm