(4)  Make sure earth connected before operation 

     

There is a grounding screw on the back of machine with a grounding sign beside. Before using, make sure 
earth connected well to prevent the operator from getting electric shock or electricity leak. Please use 
10mm

2

 cable to connect the case of the machine to earth.

(5)  Operation over max duty cycle  

 

   

 

 

When using the machine over max duty cycle, inside overheating circuit causes the temperature switch to 
be open-circuit, which finally prevents the product from working on. This can be judged from the yellow 
light LED on face panel. Under this circumstance, no need to pull off the plug from the power and keep 
power on to let the fan cool down the machine. When the yellow LED turns off, welding can be continued.

 Warning

This machine will produce electric and magnetic fields, so the operator should ensure proper protection and 
screening while using it.

    

Earth leakage-circuit breaker should be used with this machine.

    

During operation, DO NOT pull out or insert any plugs or cables. It can lead to fatal danger and cause dam-
age to the machine.

    

Before connecting cables, make sure the power is off. (The correct way is to connect the cables to the ma-
chine first, and make sure they are firmly tightened and then connect the power plug to the power source.)

    

Before maintenance and checking, power must be turned off,

    

Before opening the cover, disconnect the ma chine from power source.

1)  Remove dust with dry and clean compressed air regularly. If the welding machine is operated in polluted 

area with smoke and dust, the machine needs to be cleaned regularly.

2)  Pressure of compressed air must not be higher than 5 bars in order to prevent damage to small compo-

nents inside the machine.

3)  Check inside the welding machine regularly and make sure the output terminals are connected tightly and 

connectors are not damaged. If burnt, loose or damaged, please tighten or replace them if necessary.

4)  Avoid water and steam entering into the machine. If the welding machine gets wet, please dry inside of the 

machine and check the insulation status.

5)  If the machine will not be used for long time, it should be put into a box or covered and stored in cool and 

dry area.

6)  When power is on, do not let hand or hair touch electrification device in the machine such as fan to avoid 

injury or damage to machine.

8. Maintenance

Summary of Contents for HYMIG-200

Page 1: ...DC INVERTER MIG WELDER MIG 160 200 User Manual Original Instructions For Your Safety Read and understand this manual before use Keep this manual for future reference...

Page 2: ...this welder therefore some parts of this welder may be changed in order to achieve the better quality but the main functions and operations will not be alternated and changed Your understanding would...

Page 3: ...ty General Description Main Parameters Electric Block Diagram Operation Control and Description Installation Debugging and Operation Caution Maintenance Troubleshooting Exploded Drawing 2 4 4 5 6 7 9...

Page 4: ...et gloves clothes Make sure that you are insulated from the ground and work piece Make sure that your working position is safe Smoke gas may be harmful to health Keep the head away from smoke and gas...

Page 5: ...e center of your supplier to seek professional help if you still cannot fully understand after reading the manual or still cannot solve the problem according to the manual Safe use of the welding torc...

Page 6: ...lding dynamic characteristic control circuit in MIG stable arc little spatter beautiful weld bead high efficiency Removing tip ball after welding high no load voltage and soft start wire feeding resul...

Page 7: ...HYUNDAI 05 MIG 160 200 4 Electric Block Diagram...

Page 8: ...rheating LED b Power LED c Feed wire adjust d MMA current MIG voltage adjust knob e MMA MIG shift switch f Quick socket g Quick socket h European connector of the welding torch in MIG Back panel i Gas...

Page 9: ...the cable plug with work clamp into the output terminal f on the front panel of the machine and tighten it clockwise 3 Generally DCEP connection and DCEN connection are available in MMA DCEP Connect t...

Page 10: ...he groove size in the feeding position on the drive roll matches the contact tip size of the welding torch and the wire size Release the pressure arm of the wire feeder to thread the wire through the...

Page 11: ...current over voltage over heating protection circuit is installed in this machine If the input voltage or the output current is too high or machine inside temperature over heating inside the machine w...

Page 12: ...dam age to the machine Before connecting cables make sure the power is off The correct way is to connect the cables to the ma chine first and make sure they are firmly tightened and then connect the...

Page 13: ...it does not work it indicates that the power cord is not in good contact 2 If the fan works it indicates that the control PCB inside the machine fails There is no response when pushing the torch trig...

Page 14: ...ng torch away immediately when stopping weld ing so that the shielded gas can protect the weld bead 2 Prolong the post flow time of the shield gas and contact our company Correct Disposal of this prod...

Page 15: ...otective ring 11 Middle case 12 Plastic panel 13 Indicator 14 Reactor 15 MMA MIG switch 16 Potentiometer 17 Euro socket 18 Latch catch 19 Foot pad 20 Bottom case 21 Left side case 22 Grounding screw 2...

Page 16: ......

Page 17: ...HYUNDAI Corporation 25 Yulgok ro 2 gil Jongno gu Seoul 03143 Korea Post Code 03143 82 2 390 1114 www hyundaicorp com Copyright HYUNDAI Corporation All rights reserved Made in P R C...

Reviews: