background image

HYUNDAI

02

MIG

-160/200

Welding is dangerous, and may cause damage to you and others, so take good protection when welding. For 
details, please refer to the operator safety guidelines in conformity with the accident prevention requirements 
of the manufacturer.

Professional training is needed before operating the machine.

  

Use labor protection welding supplies authorized by national security supervision department.

  

The operator must be qualified personnel with a valid “metal welding (OFC) operations” operation certificate.

  

Cut off power before maintenance or repair.

Electric shock—may lead to serious injury or even death.

  

Install earth device according to the application criteria.

  

Never touch the live parts when skin bore or wearing wet gloves/clothes.

  

Make sure that you are insulated from the ground and work piece.

  

Make sure that your working position is safe.

Smoke & gas—may be harmful to health.

  

Keep the head away from smoke and gas to avoid inhalation of exhaust gas from welding.

  

Keep the working environment in good ventilation with exhaust or ventilation equipment when welding.

Arc radiation—may damage eyes or burn skin.

  

Wear suitable welding masks and protective clothing to protect your eyes and body.

  

Use suitable masks or screens to protect spectators from harm.

Improper operation may cause fire or explosion.

    

Welding sparks may result in a fire, so please make sure no combustible materials nearby and pay attention 
to fire hazard.

  

Have a fire extinguisher nearby, and have a trained person to use it.

  

Airtight container welding is forbidden

    

Must not use the machines for other purposes except welding, such as pipe thawing, battery charging, 
heating.

1. Safety

Summary of Contents for HYMIG-200

Page 1: ...DC INVERTER MIG WELDER MIG 160 200 User Manual Original Instructions For Your Safety Read and understand this manual before use Keep this manual for future reference...

Page 2: ...this welder therefore some parts of this welder may be changed in order to achieve the better quality but the main functions and operations will not be alternated and changed Your understanding would...

Page 3: ...ty General Description Main Parameters Electric Block Diagram Operation Control and Description Installation Debugging and Operation Caution Maintenance Troubleshooting Exploded Drawing 2 4 4 5 6 7 9...

Page 4: ...et gloves clothes Make sure that you are insulated from the ground and work piece Make sure that your working position is safe Smoke gas may be harmful to health Keep the head away from smoke and gas...

Page 5: ...e center of your supplier to seek professional help if you still cannot fully understand after reading the manual or still cannot solve the problem according to the manual Safe use of the welding torc...

Page 6: ...lding dynamic characteristic control circuit in MIG stable arc little spatter beautiful weld bead high efficiency Removing tip ball after welding high no load voltage and soft start wire feeding resul...

Page 7: ...HYUNDAI 05 MIG 160 200 4 Electric Block Diagram...

Page 8: ...rheating LED b Power LED c Feed wire adjust d MMA current MIG voltage adjust knob e MMA MIG shift switch f Quick socket g Quick socket h European connector of the welding torch in MIG Back panel i Gas...

Page 9: ...the cable plug with work clamp into the output terminal f on the front panel of the machine and tighten it clockwise 3 Generally DCEP connection and DCEN connection are available in MMA DCEP Connect t...

Page 10: ...he groove size in the feeding position on the drive roll matches the contact tip size of the welding torch and the wire size Release the pressure arm of the wire feeder to thread the wire through the...

Page 11: ...current over voltage over heating protection circuit is installed in this machine If the input voltage or the output current is too high or machine inside temperature over heating inside the machine w...

Page 12: ...dam age to the machine Before connecting cables make sure the power is off The correct way is to connect the cables to the ma chine first and make sure they are firmly tightened and then connect the...

Page 13: ...it does not work it indicates that the power cord is not in good contact 2 If the fan works it indicates that the control PCB inside the machine fails There is no response when pushing the torch trig...

Page 14: ...ng torch away immediately when stopping weld ing so that the shielded gas can protect the weld bead 2 Prolong the post flow time of the shield gas and contact our company Correct Disposal of this prod...

Page 15: ...otective ring 11 Middle case 12 Plastic panel 13 Indicator 14 Reactor 15 MMA MIG switch 16 Potentiometer 17 Euro socket 18 Latch catch 19 Foot pad 20 Bottom case 21 Left side case 22 Grounding screw 2...

Page 16: ......

Page 17: ...HYUNDAI Corporation 25 Yulgok ro 2 gil Jongno gu Seoul 03143 Korea Post Code 03143 82 2 390 1114 www hyundaicorp com Copyright HYUNDAI Corporation All rights reserved Made in P R C...